Electrical connection:
Before the machine is connected to the mains, control that the voltage and frequency printed on the name plate
correspond with the installation location.
The name plate is positioned uppermost on the back of the machine.
The machine is equipped with a 1-phase VFD ( Variable-frequency drive), together with the built-in filter, EMC/
EMI and leakage currents are reduced to a minimum.
The machine must be grounded in accordance with the applicable safety standards.
Failure to do so may cause -
Risk of electrical shock.
Damage to the machine.
Excessive electromagnetic noise, causing malfunction to the machine and interference to other devices.
When upstream protection by means of a “residual current device” is required by the installation standards, a
type A circuit breaker should be used.
User can connect machine if -
Cable with plug is delivered with the machine
Only certified electrician must connect the machine, if the machine is delivered without a plug.
For the benefit of service staff, it should be clear to see when the mains plug to the mixer has been removed from
the socket in the wall.
The machine is equipped with strong permanent magnets. By maintaining a safe distance (between the field source and
implant) of 30 cm, any impact on active implants (e.g. pacemakers, defibrillators) can likely be prevented.
Magnets:
Warning for users with implants (e.g. pacemakers, defibrillators).
Machine and safety guard equipped with strong magnets
Areas on machine and
bowl with magnets -
for bowl detection
Area on machine
with magnets - for
safety guard switch
Area on safety guard
with magnets
4