MST-5C USER’S GUIDE
Section C-24
MST-5C
TIMER
on
off
REL
Normal Mode Settings
Set Point (POS 1)
Main Set Point
This is the temperature goal for the room, the activation temperature for
stage 1 and the reference temperature for all relative settings. The
Main
Set Point
will follow its growth curve when the
Growth Day
is not
OFF
and the
MSP Curve
option is set to
ON
. The growth curve is composed
of four day-points and four temperature-points. To adjust these points,
press the SET/CLR button. Then select the point to adjust using the F2
button and adjust it with the adjustment knob. See the
Additional
information on parameters
section for more information on the growth
curve. The
Main Set Point
is adjusted in 0.1° increments from
-40.0°F to 100.0°F (-40.0°C to 37.8°C).
Stage 1 (POS 2)
Stage 1 Cycle
This parameter is used to establish the duration of the run time for the stage
1 timer. When the
Average Temperature
is below
Main Set Point
, stage 1
will be activated for a percentage (
Stage 1 Cycle
) of the
Stage 1 Period
. If
Stage 1 Cycle
is set to OFF, stage 1 will never activate below
Main Set
Point
. If
Stage 1 Cycle
is set to ON, stage 1 will be continuously activated
below
Main Set Point
. This parameter is adjusted in 1% increments from
OFF, 1% to 99%, ON.
Stage 1 Period
Per
This parameter is used to establish the duration of the period for the stage 1
timer. When the
Average Temperature
is below
Main Set Point
, stage 1
will be activated for a percentage (
Stage 1 Cycle
) of this period. This
parameter is adjusted in 1-minute increments from 1 to 10 minutes.
Stage 2 (POS 3)
Relative Temperature Stage 2
This parameter is used to establish the relative temperature at which stage
2 will activate. When the
Average Temperature
reaches
Main Set Point
+
Relative Temperature Stage 2
, stage 2 will activate. If DIPSW6 is OFF
(see DIP Switches and Slide Switches Table page 38), stage 1 will shut off
as long as stage 2 is activated. This parameter is adjusted in 0.1°
increments from 0.5°F to 20.0°F (0.3°C to 11.1°C).
www.monitrol.com
Summary of Contents for MST-5C
Page 3: ...MST 5C WIRING DIAGRAM MST 5C Section A 3 WIRING DIAGRAM MST 5C SECTION A www monitrol com ...
Page 6: ...MST 5C INSTALLATION Section B 6 MST 5C INSTALLATION MST 5C SECTION B www monitrol com ...
Page 19: ...MST 5C USER S GUIDE MST 5C Section C 19 USER S GUIDE MST 5C SECTION C www monitrol com ...
Page 43: ...MST 5C INDEX WARRANTY MST 5C Section D 43 INDEX WARRANTY MST 5C SECTION D www monitrol com ...
Page 47: ...www monitrol com ...
Page 48: ...MST 5C_EN VER 1 3 November 20 2012 www monitrol com ...