O
PERATION
: DMX O
PERATION
02.9703.0001 A
17 December 2012
39
Control Channel Functions - Mode 2
Table 3-6: Control Channel Functions - Mode 2
DMX Channel
Control Channel Function
Control Channel DMX Value
41
Default Setting on Console
0
Display On / Off
3 - 4
Reset All to Defaults**
5 - 7
Quiet Mode
†
11 - 13
Level Light Mode
†
14 - 16
Constant Fans Mode
†
17 - 19
Normal Mode
†
20 - 22
Dimmer Curve LINEAR
†
31 - 32
Dimmer Curve SQUARE LAW
†
34 - 35
Full Luminaire Reset
81 - 87
Color Calibration OFF
†
116 - 117
Color Calibration ON
†
118 - 120
Manual Color Adjust ENABLE†
121 - 122
Manual Color Adjust STORE†
124 - 125
Engines Combined#
150 - 152
Engines Independent#
153 - 155
Notes:
** When resetting to defaults, the following will be enabled on the luminaire:
•
Normal Mode
•
Dimmer Curve SQUARE LAW
•
Color Calibration ON
† These settings require the Command Lock in Menu to be set to OFF in order to change on Control Chan-
nel. Resetting to defaults will turn Command Lock OFF.
# This parameter does not require that the value be held for 3-seconds to set. NOTE: In Combined Mode, all
fixtures must be patched as Mode 2 units (41 channel) for proper operation.
Summary of Contents for VLX3
Page 1: ......
Page 13: ...FOREWORD 02 9703 0001 A 17 December 2012 xi...
Page 14: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL xii 17 December 2012 02 9703 0001 A...
Page 36: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 20 17 December 2012 02 9703 0001 A Notes...
Page 84: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 68 17 December 2012 02 9703 0001 A Notes...
Page 97: ......