Control
0 - 255
0 - 100%
0
Used to set different modes, parameters, and
functions of the VLX Wash. Set control channel
value for desired action. Hold value for at least 3
seconds (unless noted by #). Set control channel
value to 0 without any scaling.
Default Setting on Console = DMX 0
Display On/Off = DMX 3-4
Reset All to Defaults** = DMX 5 - 7
Quiet Mode† = DMX 11 - 13
Level Light Mode† = DMX 14 -16
Constant Fans Mode† = DMX 17 - 19
Normal Mode† = DMX 20 - 22
Dimmer Curve LINEAR† = DMX 31 - 32
Dimmer Curve SQUARE LAW† = DMX 34 - 35
Full Luminaire Reset = DMX 81 - 87
Color Calibration OFF† = DMX 116 - 117
Color Calibration ON† = DMX 118 - 120
Manual Color Adjust ENABLE† = DMX 121 - 122
Manual Color Adjust STORE† = DMX 124 - 125
Engines Combined# = DMX 150 -152
Engines Independent# = DMX 153 - 155
Notes:
** When resetting to defaults, the following will be
enabled on the luminaire:
- Normal Mode
- Dimmer Curve SQUARE LAW
- Color Calibration ON
† These settings require the Command Lock in
Menu to be set to OFF in order to change on
Control Channel. Resetting to defaults will turn
Command Lock OFF.
# This parameter does not require that the value
be held for 3-seconds to set. NOTE: In Com-
bined Mode, all fixtures must be patched as
Mode 2 units (41 channel) for proper operation.
Table 3-2: VLX3 Wash Luminaire Mapping Mode 2
Summary of Contents for VLX3
Page 1: ......
Page 13: ...FOREWORD 02 9703 0001 A 17 December 2012 xi...
Page 14: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL xii 17 December 2012 02 9703 0001 A...
Page 36: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 20 17 December 2012 02 9703 0001 A Notes...
Page 84: ...VARI LITE VLX3 WASH LUMINAIRE USER S MANUAL 68 17 December 2012 02 9703 0001 A Notes...
Page 97: ......