![background image](http://html1.mh-extra.com/html/vari-lite/vl2402/vl2402_user-manual_3515479029.webp)
I
NSTALLATION
: P
OWER
AND
D
ATA
C
ABLING
R
EQUIREMENTS
2
0 2 . 9 6 7 1 . 0 0 0 1 C
17 - Se pt - 01
11
Power and Data Cabling Requirements
Power
The luminaire requires standard AC power distribution from 90-264 VAC, 50/60 Hz.
Four amps to twelve amps will be required depending on the AC supply voltage and
product model.
Depending on the application, the luminaire’s AC input cable may require a different
connector. If required, install a new connector meeting your requirements using the
following wire color code reference:
* International (Harmonized) Standard
WARNING:
DO NOT connect to three-phase service in countries with 240 volt
power.
For single-phase power at 100 to 240 volts RMS:
For three-phase power at 208 volts RMS:
Wire*
Connection
Green/Yellow
AC Ground
Blue
AC Neutral
Brown
AC Line
Connection
Pin
AC Neutral
X
AC Line
Y
Ground (Earth)
G
Connection
Pin
Phase 1
X
Phase 2
Y
Ground (Earth)
G
X
Y
G
X
Y
G