0 2 . 9 6 7 1 . 0 0 0 1 C
17 - Se pt - 01
91
Routine Maintenance
Lamp Replacement
WARNING:
Remove power from luminaire before performing maintenance.
Parts:
700 Watt Short-Arc Lamp (Vari-Lite part: 71.2528.0700)
Tools:
Screwdriver, slotted
Cotton gloves
To replace lamp:
1. Remove power from luminaire.
WARNING:
Lamps will be extremely HOT after operation. Allow lamp to cool
before replacing.
2. At backcap, using slotted screwdriver (or
fingers) turn captive knob until loose. See
Figure A-1
.
3. Slide backcap away from head assembly
(it will remain attached by tether and lamp
wires).
Figure A-1: Lamp Replacement
Captive Knob
Backcap Assembly
Head Assembly
Guide Rod
Lamp