background image

VL2

402

 

Wash

 Luminaire

User’s

 

 

 

Manual

02.9671.0001

Summary of Contents for VL2402

Page 1: ...VL2402 Wash Luminaire U s e r s M a n u a l 02 9671 0001...

Page 2: ...081 BE FR GB 0192882 BE FR GB 0140994 BE FR GB 0060068 BE FR GB France Design Reg No 335132 335147 Spain Patents No 2090191 2084289 2082384 2058071 2020960 0548328 Spain Utility Model No 2031748 Spain...

Page 3: ...ber of the item being returned a description of the problem or failure and the name of the registered user or organization If available you should have your sales invoice to establish the date of sale...

Page 4: ...rference to radio communica tions Operation of this equipment in a residential area is likely to cause harmful inter ference in which case the user will be required to correct the interference at his...

Page 5: ...e only with certain Philips and Osram HID lamps Note lamp type MSR400 MSR575HR etc before replacing lamps Installing another type of lamp may be hazardous 2 Luminaires may be mounted on any type of su...

Page 6: ...n which can cause serious skin burn and eye inflammation Additionally arc lamps operate under high pressure at very high temperatures Should the lamp break there can exist a danger of personal injury...

Page 7: ...MSR575HR etc bevor Sie die jeweiligen Lampen ersetzen Die Installation eines anderen Lampentyps kann gef hrlich sein 2 Scheinwerfer k nnen auf jeder beliebigen Oberfl che montiert werden solange Sie...

Page 8: ...lampen erfolgt unter Hochdruck und bei hohen Temperaturen Sollte die Lampe zerbrechen besteht die Gefahr von K rperverletzung bzw von Feuer das von Lampenteilen ausgel st werden kann 4 Tragen Sie beim...

Page 9: ...es lampes Philips et Osram HID V rifier le type de lampe MSR400 MSR575HR etc avant de remplacer les lampes L installation d un autre type de lampe peut poser un danger 2 Les luminaires peuvent tre fix...

Page 10: ...raves br lures sur la peau et une inflammation des yeux De plus les lampes arc fonctionnent sous haute tension de tr s hautes temp ratures Si la lampe se casse les particules de la lampe cass e peuven...

Page 11: ...s l mparas HID Philips y Osram Tome nota del tipo de l mpara MSR400 MSR575HR etc antes de reemplazarla Instalaci n de otro tipo de l mpara puede ser peligroso 2 Las luminarias se pueden instalar en cu...

Page 12: ...la piel e inflamaci n a los ojos Adem s las l mparas de arco operan a alta presi n y muy alta temperatura Si la l mpara se rompe puede existir el peligro de lesiones al personal o un incendio ocasion...

Page 13: ...i _KH P H P Q X Q X _KH P s H P T Q X _KQo 4 UV 2 q P x T 4 Ef 1 VARI LITE zU Philips Osram HID fJ 3 fJ d fJ MSR400 MSR575HR z fJ zU Q X 0 2 2 J Y f Q X EXo d EXo 4 VARI LITE zU H 6 T Ef 1 VARI LITE z...

Page 14: ...671 0001 C T 2 UV Ef 1 VARI LITE zU UV HID 2 J fJ fJ _f o zU P _f o Y 2 T q P Ef zU P zU fPo f U zU P fJ fJ d zU fJ 2 fJ c 64 fJ o v o A 6 o q P 4 H cP fJ U fJ H o fJ zU I fJ fJ T RF 1 Class A 8c u H...

Page 15: ...wer 11 Current vs Voltage 12 Data Cables 13 Recommended Cable Types Manufacturers 14 Male Termination Connector 15 Loopback Connector 15 Installation Procedures Installing Lamp 16 Hanging the Luminair...

Page 16: ...minaire 46 Hardware Requirements 46 Transfer Procedure 46 Chapter 4 Menu System Operation What Is the Menu System 51 Controls Operation 51 Display Orientation 52 Default State 53 Decimal Placement 53...

Page 17: ...ept 01 xvii Routine Maintenance Lamp Replacement 91 Color Filter Replacement 93 Cleaning Optical Lenses and Filters 95 Appendix B Technical Specifications Mechanical 97 Optical 98 Operational 98 Photo...

Page 18: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL xviii 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 19: ...al is available for extended maintenance of VL2402 Wash Luminaires This manual is available in both printed and electronic PDF formats VL2402 Wash Luminaire Service Manual 02 9671 0010 Troubleshooting...

Page 20: ...Conventions The following styles and meanings are used throughout this manual Button Front panel button Example Press Menu Up Down arrows Press either Up or Down arrow button at Menu Display MENU Menu...

Page 21: ...02 9671 0001 C 17 Sept 01 3 Description Description Description Description Features Components CHAPTER 1 CHAPTER 1...

Page 22: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 4 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 23: ...atures Zoomable beam spreader Crossfading color mixer mechanism The mechanism allows independent blue amber and magenta color control Fixed Color wheel has 12 positions 1 open for dichroic color An in...

Page 24: ...ead Assembly Upper Enclosure Truss Hook Assembly AC Input Cable Yoke Bracket Assembly Assembly Removable Lamp Assembly to access lamp for replacement Vertical Horizontal Focus Captive Knob for lamp ac...

Page 25: ...splay orientation and operation LED Indicators The LED indicators report the status of power and data to the luminaire Changes a value or Displays the menu or if at first level the current address Sel...

Page 26: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 8 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 27: ...02 9671 0001 C 17 Sept 01 9 Installation Installation Installation Installation Power and Data Cabling Requirements Installation Procedures Powering Up Addressing CHAPTER 2 CHAPTER 2...

Page 28: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 10 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 29: ...AC input cable may require a different connector If required install a new connector meeting your requirements using the following wire color code reference International Harmonized Standard WARNING...

Page 30: ...ides the luminaire s current draw at specific voltages Current is calculated with the lamp on and all motors sequencing Table 2 1 VL2402 Current vs Voltage Voltage 60Hz Current 90 0 11 8 100 0 10 6 11...

Page 31: ...ow capacitance Two twisted pairs Foil and braid shielded 24 AWG min gauge for runs up to 1000 feet 300m 22 AWG min gauge for runs up to 1640 feet 500m Note Microphone type cables and other general pur...

Page 32: ...Temp Plenum cable 200 8102 2 100 PVC 24 UL2919 80 8132 2 120 PVC 28 UL2919 80 8162 2 100 PVC 24 UL2493 60 82729 2 100 PTFE 24 High Temp Plenum cable 200 88102 2 100 PTFE 24 High Temp Plenum cable 200...

Page 33: ...on connector is available as an accessory from Vari Lite See Accessories on page 101 Loopback Connector When transferring software versions from luminaire to luminaire a loopback connector is required...

Page 34: ...ure power is removed from luminaire 2 Remove lamp from shipping box 3 At backcap using slotted screwdriver or fingers turn captive knob until loose 4 Slide backcap away from head assembly it will rema...

Page 35: ...truss hook bracket are required When attaching more than one point on a single bracket the attach points must be spaced as far apart as possible using the supplied mounting holes A safety cable is re...

Page 36: ...lock in place Ensure brackets are locked securely Always face brackets in same direction as shown WARNING Ensure that the bracket locking mechanism is fully seated after the bracket is installed on th...

Page 37: ...llows a Connect one end of cable to luminaire handle b Loop at least once around truss pipe and attach other end of cable to other handle 4 Connect power and data cables according to procedure given i...

Page 38: ...Consult your console documentation for more information To connect power and data 1 Connect data cable from console to first luminaire in chain at DATA IN connector 2 If required connect additional da...

Page 39: ...is present All internal mechanisms also move to their home or DMX defined positions Subsequently depending on the luminaire s setting for Lamp Power Up State refer to Menu System Functions on page 58...

Page 40: ...t WARNING Backcap and adjustment knobs will be HOT during lamp operation Wear gloves and or use tools to prevent burns To align lamp 1 Using internal menus select Lamp test to set beam See Lamp on pag...

Page 41: ...button until DMX appears Press Enter 3 Press Up or Down to until desired mode is reached 8 16 E 8 or E 16 Press Enter to set mode See DMX Modes on page 29 for more information Note Which mode is used...

Page 42: ...a DMX or Virtuoso starting address 1 Press Menu 2 Press Up Down arrows until ADDR Address appears Press Enter 3 Press Up Down arrows to access DMX DMX console control or VIRT Virtuoso protocol Press...

Page 43: ...02 9671 0001 C 17 Sept 01 25 Operation Operation Operation Operation Color Control DMX Modes DMX Mapping Luminaire Timing Updating Software CHAPTER 3 CHAPTER 3...

Page 44: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 26 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 45: ...n of the Snap is based on the last command executed Snap will not change until another value of 20 25 or 30 35 is entered into the control channel Resetting the luminaire or cycling the power will not...

Page 46: ...me positions The color wheel has 12 positions one being open It offers partial frame control and various spin rates in either direction The following illustration shows the standard color configuratio...

Page 47: ...hannel Function DMX Channel Dimmer 1 Dimmer 1 Pan 2 Pan 2 3 Tilt 3 Tilt 4 5 Blue 4 Blue 6 Amber 5 Amber 7 Magenta 6 Magenta 8 Color Wheel 7 Color Wheel 9 Diffusion 8 Diffusion 10 Strobe 9 Strobe 11 Co...

Page 48: ...eel Position DMX 0 100 DMX 0 255 Wheel Position 0 0 Open Frame 1 29 1 30 2 12 31 1 3 32 4 13 33 2 5 34 6 35 7 14 36 Full Frame 3 3 8 37 9 Half Frame 15 38 4 10 39 11 40 12 16 41 5 13 42 14 17 43 6 15...

Page 49: ...9 103 70 104 28 71 41 105 72 Full Frame 5 106 73 42 107 29 74 108 Full Frame 7 75 109 30 76 43 110 77 111 78 44 112 31 79 113 80 Half Frame 114 81 45 115 32 82 116 Half Frame 83 46 117 33 84 118 85 11...

Page 50: ...67 53 135 66 168 136 169 137 170 Half Frame 54 138 67 171 139 172 55 140 68 173 141 174 142 175 56 143 69 176 144 Full Frame 9 177 57 145 178 146 70 179 147 180 Full Frame 11 58 148 71 181 149 182 59...

Page 51: ...Stop 202 92 235 Stop 203 236 Stop 80 204 93 237 Spin S CW 205 238 206 Half Frame 239 81 207 94 240 208 241 82 209 95 242 210 243 211 244 83 212 96 245 213 246 Spin M CW 84 214 97 247 215 248 216 Spin...

Page 52: ...Value Action 0 0 2 Open 1 3 5 Closed 2 6 7 Slow Random 3 8 10 Med Random 4 11 12 Fast Random 5 100 13 255 Speed Range Table 3 3 DMX Map for Blue Value DMX Value Action 0 0 Open 100 255 Closed or Full...

Page 53: ...de which fixtures and which parameter groups will use timing channels Timing channels work only if all channels affected by the timing channel are in the same part of the cue 3 Assign a value to the p...

Page 54: ...MANUAL 36 17 Sept 01 02 9671 0001 C Table 3 6 Channel Function Timing Channel Relationship Channel Function Timing Channel Focus Time Color Time Beam Time Pan Hi Byte Lo Byte Tilt Hi Byte Lo Byte Blu...

Page 55: ...4 7 1 4 17 43 8 6 3 8 1 6 44 8 8 9 1 8 45 9 4 10 2 18 46 9 2 11 2 2 47 9 4 12 2 4 19 48 9 6 5 13 2 6 49 9 8 14 2 8 50 10 6 15 3 20 51 10 2 16 3 2 52 10 4 17 3 4 53 10 6 7 18 3 6 21 54 11 19 3 8 55 11...

Page 56: ...18 36 83 23 119 37 33 84 23 47 120 37 85 23 121 38 86 24 48 122 38 34 87 24 123 38 88 25 124 39 35 89 25 49 125 39 90 25 126 39 91 26 127 40 36 92 26 50 128 40 93 27 129 41 37 94 27 51 130 41 95 27 13...

Page 57: ...5 61 156 51 192 85 157 52 193 90 62 158 52 76 194 90 159 52 195 95 160 53 77 196 95 63 161 53 197 95 162 54 198 100 64 163 54 78 199 100 164 54 200 110 165 55 79 201 110 65 166 55 202 110 167 56 203 1...

Page 58: ...180 94 240 260 221 190 241 270 87 222 190 95 242 270 223 200 243 270 88 224 200 244 280 225 200 96 245 280 226 210 246 290 89 227 210 97 247 290 228 210 248 290 229 220 249 300 90 230 220 98 250 300...

Page 59: ...er or fader does not allow for a quick value change which is required to affect the control functions 3 Set control channel value to zero This must occur without any scaling values Action will be void...

Page 60: ...r the VL2000 Luminaire Note Up to 32 luminaires can be programmed at the same time if they are data linked together Refer to Connecting Data and Power on page 20 Programming more than 32 luminaires wi...

Page 61: ...d exe program from Vari Lite Series 2000 support webpage 1 From PC that will be used to operate software connect to Vari Lite Series 2000 support webpage at www vari lite com See Reprogramming Luminai...

Page 62: ...d All button is the equivalent of executing all of the specific software version buttons described above They will be executed one at a time in the order they appear in the window This button can be u...

Page 63: ...onnected the normal standby cycle of the Rx LED is 2 sec on 2 sec off 5 Once download is complete luminaire will automatically recalibrate Once recalibration is complete luminaire is ready for operati...

Page 64: ...ata Cables on page 13 A loopback connector is required at the first luminaire and a male termination connector is required at the last luminaire Refer to page 15 for more information regarding the con...

Page 65: ...is the 5 conductor type Note Without any data connected the normal standby cycle of the Rx LED is 2 sec on 2 sec off Note The number of blocks displayed will be less in a luminaire to luminaire downl...

Page 66: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 48 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 67: ...02 9671 0001 C 17 Sept 01 49 Menu System Menu System Menu System Menu System Operation Mapping Cues and Sequences Self Tests CHAPTER 4 CHAPTER 4...

Page 68: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 50 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 69: ...tons These buttons function as follows Menu button Displays the menu or if at first level the current address Can also enable menu to exit a menu level Enter button Selects the current menu option or...

Page 70: ...To assist in reading the Menu System if the luminaire is installed in a hanging position the display read out orientation can be changed so that it still reads from left to right Keep in mind that wh...

Page 71: ...ion appears Press Enter 3 Press Up Down arrows to access DisP Display Press Enter 4 Press Up Down arrows to select either 30s 30 sec 5M 5 minutes 10M 10 minutes or ON on indefinitely Press Enter to se...

Page 72: ...ssing Enter and Up at the same time Lamp On Pressing Enter and Down at the same time Lamp Off Pressing Menu and Up at the same time Recalibrate Pressing Menu at Power up interrupts calibration See Pro...

Page 73: ...or 1 Magenta Sensor Not Found B1M1 MAG SAct Aux Board 1 Motor 1 Magenta Sensor Always Active B1M2 Dimm NoSn Aux Board 1 Motor 2 Dimmer Sensor Not Found B1M2 Dimm SAct Aux Board 1 Motor 2 Dimmer Sensor...

Page 74: ...RE USER S MANUAL 56 17 Sept 01 02 9671 0001 C TILT NO SENS Tilt Sensor Not Found TILT SENS ACTV Tilt Sensor Always Active WAIT Retrieving Current Status WRNG SW PROG Wrong Software Program Table 4 1 E...

Page 75: ...rt Menu stop MODE DATA cXXX data value value Sens Pan Tilt Dimm CWhl Blue Ambr MAG Fixt STAT Cal Modl LId pg 1 model OK scrolls errors or displays OK Ver FHrs Dnld pg 2 pg 1 pg 2 OK DSEQ OK STST STST...

Page 76: ...peration Hours Not editable Strk of Lamp Strikes XXXX of Strikes not editable RHrs Reset Lamp Hour and Lamp Strike Counters OK P T Pan and Tilt Options Move Pan Tilt Control Enab Enable Dis Disable SN...

Page 77: ...AG Magenta XXX Data DIFF Diffusion XXX Data Time Timing Data ITim Dimmer Intensity Time XXX X Data FTim Focus Time XXX X Data CTim Color Time XXX X Data BTim Beam Time XXX X Data Cue Cue Processing FL...

Page 78: ...t Dim3 Dimmer Test Strb Strobe Test CWhl Color Wheel CW1 Color Wheel Test CW2 Color Wheel Test CW3 Color Wheel Test Blue Blue Bl 1 Min Max Blue Test Bl 2 Min Max Blue Test Bl 3 Blue Test Ambr Ambr Amb...

Page 79: ...robe EOT Sensor STST Sensor Test in Progress PASS FAIL CWhl Color Wheel EOT Sensor STST Sensor Test in Progress PASS FAIL Blue Blue EOT Sensor STST Sensor Test in Progress PASS FAIL Ambr Amber EOT Sen...

Page 80: ...me Accepts timing value for beam time C ON On after Calibration Configures arc luminaire so that lamp will strike after calibration procedure is complete Cal Re calibrate Re calibrates luminaire CFG S...

Page 81: ...ade time L ON Lamp is On Configures arc luminaire so that lamp will strike upon power up LAMP Lamp Accesses lamp power up options and information CFG and sets beam for lamp alignment adjustment TEST L...

Page 82: ...g SEQ Sequence Playback Sets sequence playback mode to Individual plays cues from each luminaire or Master all luminaires play same cue SNAP Snap Enables disables the colors Blue Amber or Magenta taki...

Page 83: ...n a master luminaire Playing a cue sequence for all luminaires in the data link is triggered by a master luminaire using the PSEQ Play Sequence command The cue follow time FLTM is taken from the lumin...

Page 84: ...naire will be the basis of the cue to be stored To clear all input data and timing values from previous tests or cues cycle power to the luminaire with DMX data cables disconnected This will reset par...

Page 85: ...s the cue number to be stored 4 Press Enter to store cue Number will increase by one for next cue to be stored 5 Repeat for remaining cues To delete a cue 1 Press Menu 2 Press Up Down arrows until Cue...

Page 86: ...Cue appears Press Enter 3 Press Up Down arrows until PSEQ appears Press Enter and the sequence will play The active cue will be shown in the display Enter to start Menu to stop To change the follow t...

Page 87: ...appears Press Enter 4 Press Up Down arrows to toggle between ISEQ and MSEQ Press Enter to select mode To make a sequence AutoPlay at power up 1 Press Menu 2 Press Up Down arrows until Cue appears Pre...

Page 88: ...any position for testing without movement occurring In order to regain full control of the luminaire Move will need to be enabled after testing Note When setting the Move option to disable luminaires...

Page 89: ...01 C 17 Sept 01 71 3 Use Up Down arrows to select a parameter to test Refer to Menu System Functions on page 58 for a complete list of test parameters which can be chosen 4 Press Enter to run test 5 P...

Page 90: ...pin Cw 2 Tests color wheel stabilizers Performs Max reverse spin stops on a color and then stops on the sensor Cw 3 Test color wheel stabilizers Steps through selected colors DiF1 Fast diffusion test...

Page 91: ...T only 65535 65535 0 255 0 0 0 0 0 7 7 P T only 0 0 0 0 0 0 0 0 0 7 7 P T only 65535 65535 0 0 0 0 0 0 0 7 7 P T only 45167 27000 255 0 35 0 0 0 0 0 3 45167 27000 255 0 143 0 0 0 11 0 2 45167 27000 2...

Page 92: ...4 4 Col only 45167 27000 255 150 0 0 0 255 0 4 4 Col only 45167 27000 35 0 255 0 0 0 0 0 1 65 45167 27000 255 0 161 0 0 0 0 0 1 45167 27000 35 0 216 0 0 0 0 0 1 89 45167 27000 255 0 71 0 255 0 0 0 1...

Page 93: ...167 0 0 0 0 0 0 0 0 9 9 45167 65535 0 0 0 0 0 0 0 9 9 T 3 45167 32767 0 0 0 0 0 0 0 0 1 2 45167 11207 0 0 0 0 0 0 0 0 1 45167 4487 0 0 0 0 0 0 0 0 1 45167 11207 0 0 0 0 0 0 0 0 1 45167 4487 0 0 0 0 0...

Page 94: ...167 27000 0 0 0 0 0 0 0 0 1 45167 27000 0 0 0 0 0 0 4 0 1 45167 27000 0 0 0 0 0 0 11 0 4 45167 27000 0 0 0 0 0 0 0 0 1 45167 27000 0 0 0 0 0 0 255 0 3 45167 27000 0 0 0 0 0 0 4 0 1 45167 27000 0 0 0 0...

Page 95: ...5167 27000 0 0 89 0 0 0 0 0 0 4 45167 27000 0 0 179 0 0 0 0 0 0 4 45167 27000 0 0 0 0 0 0 0 0 0 4 Bl 1 45167 27000 0 0 0 255 0 0 0 0 0 4 45167 27000 0 0 0 0 0 0 0 0 0 4 Bl 2 45167 27000 0 0 0 255 0 0...

Page 96: ...4 45167 27000 0 0 0 0 200 0 0 0 0 4 45167 27000 0 0 0 0 150 0 0 0 0 4 45167 27000 0 0 0 0 175 0 0 0 0 4 45167 27000 0 0 0 0 170 0 0 0 0 4 45167 27000 0 0 0 0 190 0 0 0 0 4 45167 27000 0 0 0 0 50 0 0 0...

Page 97: ...27000 0 0 0 0 0 50 0 0 0 4 45167 27000 0 0 0 0 0 220 0 0 0 4 45167 27000 0 0 0 0 0 200 0 0 0 4 45167 27000 0 0 0 0 0 205 0 0 0 4 45167 27000 0 0 0 0 0 100 0 0 0 4 45167 27000 0 0 0 0 0 255 0 0 0 4 451...

Page 98: ...27000 0 0 0 50 205 220 0 0 0 4 45167 27000 0 0 0 220 200 200 0 0 0 4 45167 27000 0 0 0 200 220 205 0 0 0 4 45167 27000 0 0 0 205 50 0 0 0 0 4 45167 27000 0 0 0 255 100 0 0 0 0 4 45167 27000 0 0 0 100...

Page 99: ...0 0 2 45167 27000 0 20 0 0 0 0 0 0 2 45167 27000 0 5 0 0 0 0 0 0 2 45167 27000 0 20 0 0 0 0 0 0 2 45167 27000 0 0 0 0 0 0 0 0 2 Pan and Tilt values are 16 bit DMX and will be different from the value...

Page 100: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 82 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 101: ...ce This appendix provides instructions for troubleshooting and performing routine maintenance which may be necessary during the life of the luminaire Troubleshooting Routine Maintenance WARNING All ma...

Page 102: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 84 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 103: ...oke and head covers can be removed to check for loose connectors or obvious signs of wiring component subassembly power supply or PCB printed circuit board failure Connectors can be removed and reinst...

Page 104: ...1 Magenta Sensor Not Found Magenta power not connected motor not moving Connect Magenta motor power at motor Magenta sensor not connected Connect Magenta sensor Magenta movement restricted or impeded...

Page 105: ...Board 1 is faulty Replace aux board B1M3 CWhl SAct Aux Board 1 Motor 3 Color Wheel Sensor Always Active Color Wheel power not connected and Color Wheel aligned with sensor Connect Color Wheel power at...

Page 106: ...ect aux input connector J5 to either aux board Jumper bridge connector J1 between aux boards not connected Install jumper bridge connector J1 between aux boards BRD2 NO COMM Aux Board 2 Communication...

Page 107: ...r J2 SRCH FOR BRD1 BRD2 Searching for Board 1 or 2 Attmepting to communicate with Board 1 or Board 2 System will return either OK or an error code TILT ENCR FAIL Tilt Encoder Failure Main board pan ti...

Page 108: ...J9 End of travel sensor connector J2 disconnected Connect end of travel sensor connector J2 WAIT Retrieving Current Status System displays wait while getting status WRNG SW PROG Wrong Software Progra...

Page 109: ...Tools Screwdriver slotted Cotton gloves To replace lamp 1 Remove power from luminaire WARNING Lamps will be extremely HOT after operation Allow lamp to cool before replacing 2 At backcap using slotted...

Page 110: ...d in socket and parallel to guide rods Lamp can be damaged when inserted through reflector if not parallel to guide rods 6 Align guide rods in guide holes and slide backcap into head assembly Re tight...

Page 111: ...ter 1 Remove power from luminaire 2 At removable cover using 2 Phillips screwdriver turn two captive screws one quarter turn and remove cover It will remain attached by tether See Figure A 2 Figure A...

Page 112: ...ible at finger access cutout See Figure A 3 Figure A 3 Filter Replacement CAUTION Do not touch color filters with bare fingers Wear cotton gloves or other covering while replacing Clean with glass cle...

Page 113: ...ARNING Remove power from luminaire before performing maintenance The front lens and color filters may require cleaning after extended use A common glass cleaner can be used along with a soft lint free...

Page 114: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 96 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 115: ...ts Fixed Color Wheel Provides 11 easily loaded positions for fixed dichroic color choices Beam Size Control A zoomable beam spreader mechanism provides continuous beam size control for both rapid chan...

Page 116: ...ion and require three amps to twelve amps depending on the AC supply voltage and product model All VL2402 models operate from 90 263 10 VAC 50 60 Hz Operational Temperature 20 to 122 F 29 to 50 C Cool...

Page 117: ...ple glass in place Multiply throw distance by Tn to determine coverage To calculate Illuminance I at a specific distance D DIFFUSION CANDELA cd BEAM ANGLE degrees BEAM DIAMETER TN FIELD ANGLE degrees...

Page 118: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 100 17 Sept 01 02 9671 0001 C This page intentionally blank...

Page 119: ...APPENDIX C Vari Lite Part No Accessory 20 9625 0132 Road Case Plastic Two hole 22 9620 0194 Safety Cable Assembly 23 9623 0177 DMX Termination Connector Assembly 25 9661 0056 Loopback Connector Assemb...

Page 120: ...VARI LITE VL2402 WASH LUMINAIRE USER S MANUAL 102 17 Sept 01 02 9671 0001 C This page intentionally blank...

Reviews: