MENU CONTROLS

The menu system is controlled by  [MENU], [ENTER] and two arrow (

▲▼

) buttons. 

LCD DISPLAY AND MENU OPERATION

The LCD Display Menu system consists of several categories. Use the Menu Buttons to access and make changes 
to the menu items. When the desired menu item is reached, press the desired Menu Button to display the menu 
options and to navigate and confi gure the menu options as required.

To navigate and access menu setting/selections:

Step 1. 

Make sure unit is powered and turned on.

Step 2. 

Press [MENU] to access menu categories.

Step 3. 

Use two Arrow (

▲▼

) buttons to navigate through the various options and settings. 

Step 4. 

Once menu item is reached, press [ENTER] to access the menu item parameters.

Step 5. 

Make changes to parameters as desired.

Step 6. 

Press [ENTER] button to accept changes.

To set, edit, and save a DMX address:

Step 1. 

Press [MENU].

Step 2. 

Press [Up] / [Down] (

▲▼

) arrows until Address (DMX Address) appears. Press [Enter]. 

Step 3. 

Use [Up] / [Down] (

▲▼

) arrow buttons to select the desired digit.

Step 4. 

Once all digits are set in DMX address, press [Enter] to set.

Step 5. 

DMX displays and is saved.

STATUS BAR

The Status Bar is present at all times and displays luminaire operational information 
of the luminaire. The Status Bar contains the following information:

• 

LED

 – indicates current LED state - ON or OFF.

• 

MODE

 – indicates current mode, standard, studio and whisper mode.

• 

ERR

 – Displays a number indicating the total amount of current errors 

can cycle through short text descriptions of each error. Example: “Fan” or 
“LED”. When errors are present, messages will appear in red text. When no errors are present, NO will 
display.

• 

MAP

 – indicates 16 bits or 8 bits.

• 

ADDR

 – Displays the current DMX address for the fi xture. NOTE, when the fi xture does not detect a 

DMX input signal, the DMX address text will display in red text. 

LCD Display

Displays all data and luminaire

settings

Ÿź

Arrow Keys (Up/Down)

Menu navigation / data selection

[MENU] Button

Used to access main menu

parameters

[ENTER] Button

To select or change a setting

or data value

Summary of Contents for EVENTWASH VL800

Page 1: ...Current required depends on the AC supply voltage and product model NOTE The mating power connector is supplied however you will need to purchase or construct a cable ap propriate for your application FIGURE 1 POWER CONNECTOR Depending on the application the luminaire s AC input cable may require a different connector If required install a new connector meeting your requirements using the included...

Page 2: ...AGE AT 60HZ TOTAL LUMINAIRE CURRENT MOTOR LED CURRENT 100V 3 03A 110V 2 74A 120V 2 54A 130V 2 30A 200V 1 49A 210V 1 4A 220V 1 36A 230V 1 31A 240V 1 25A CONNECTING DATA A maximum of 32 luminaires may be connected in any one DMX data link NOTE This maximum limit applies to the luminaire daisy chain only Your system or console may require fewer luminaires on a single data link path Consult your conso...

Page 3: ...ware are required Many compatible truss hooks are available from different manufacturers for your particular needs A minimum of two hooks per luminaire is required If mounting method does not use truss hooks two attachment points per luminaire are required To install mounting hardware and brackets Step 1 Bolt each clamp to the Omega holder with screw and lock nut through the hole in the holder NOT...

Page 4: ...the inlet should be closest to the floor and the exhaust should be towards the ceiling This eliminates the possibility of one luminaire blowing exhaust air into the inlet of the luminaire next to it when the luminaires are side by side If the luminaires are stacked on top of one another in a side hang a 45 enclosure orientation with the fan inlet closest to the floor MENU OPERATION LCD DISPLAY AND M...

Page 5: ...ddress DMX Address appears Press Enter Step 3 Use Up Down arrow buttons to select the desired digit Step 4 Once all digits are set in DMX address press Enter to set Step 5 DMX displays and is saved STATUS BAR The Status Bar is present at all times and displays luminaire operational information of the luminaire The Status Bar contains the following information LED indicates current LED state ON or ...

Page 6: ...nter Up Lamp On Enter Down Lamp Off Up Down Display Invert QUICK REFERENCE DMX MAP DMX DESCRIPTION DMX DESCRIPTION 1 Intensity High 12 Blue High 2 Intensity Low 13 Blue low 3 Pan High 14 White High 4 Pan Low 15 White low 5 Tilt High 16 Color Preset 6 Tilt Low 17 Strobe Speed 7 Zoom 18 Strobe Control 8 Red High 19 Focus Timing 9 Red Low 20 Optics Timing 10 Green High 21 Color Timing 11 Green low 22...

Page 7: ...inspect unit for damage from shipping Installation and operation to be performed by qualified personnel only Use safety tether when mounting Install only in locations with adequate ventilation of at least 50cm clearance from adjacent surfaces Ensure sure that ventilation slots are not blocked Ensure that the voltage and frequency of the power supply match the power requirements of the fixture The fix...

Reviews: