background image

2

VL800 EVENTWASH   

QUICK START GUIDE

For single-phase power at 208

240V RMS:

For three-phase power at 208V RMS:

CONNECTION

PIN

CONNECTION

PIN

AC neutral

X

Phase 1

X

AC line

Y

Phase 2

Y

Ground (earth)

G

Ground (earth)

G

WARNING!

  It is not recommended to power any Vari-Lite luminaire from a dimmer - even in ‘NONDIM’ mode. 

Dimmer and non-dim modules are not suitable sources of power because their output modifi es the AC wave 
form. This may work for a short time, but will eventually result in power problems, luminaire mis-operation and/
or failure and may void the luminaire’s warranty. 

CURRENT VS. VOLTAGE

Total Luminaire Current is calculated with the LED on and all motors sequencing.

WARNING! 

It is the responsibility of the user to adequately protect supply source with a correct size and type 

circuit breaker and not overload circuits.

AC VOLTAGE AT 60HZ

TOTAL LUMINAIRE CURRENT 

(MOTOR + LED CURRENT)

100V

3.03A

110V

2.74A

120V

2.54A

130V

2.30A

200V

1.49A

210V

1.4A

220V

1.36A

230V

1.31A

240V

1.25A

 CONNECTING DATA

A maximum of 32 luminaires may be connected in any one DMX data link.

NOTE: 

This maximum limit applies to the luminaire “daisy chain” only. Your system or console may require 

fewer luminaires on a single data link path. Consult your console documentation for more information.

To connect power and data:

Step 1. 

Connect data cable from console to fi rst luminaire in chain at DATA IN connector.

Step 2. 

If required, connect additional data cables from DATA THRU connectors to DATA IN

Step 3. 

At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and 
other devices on the same DMX chain may not function properly without termination)

CHANNEL REQUIREMENTS**

DMX512 CHANNELS

DESCRIPTION

MENU DISPLAY

22 Channels

16BIT 1 Cell (Default)

22

X

Y

G

X

Y

G

Data in

Data thru

Data thru

Termination**

**DMX terminator required

for last fixture on DMX line

Summary of Contents for EVENTWASH VL800

Page 1: ...Current required depends on the AC supply voltage and product model NOTE The mating power connector is supplied however you will need to purchase or construct a cable ap propriate for your application FIGURE 1 POWER CONNECTOR Depending on the application the luminaire s AC input cable may require a different connector If required install a new connector meeting your requirements using the included...

Page 2: ...AGE AT 60HZ TOTAL LUMINAIRE CURRENT MOTOR LED CURRENT 100V 3 03A 110V 2 74A 120V 2 54A 130V 2 30A 200V 1 49A 210V 1 4A 220V 1 36A 230V 1 31A 240V 1 25A CONNECTING DATA A maximum of 32 luminaires may be connected in any one DMX data link NOTE This maximum limit applies to the luminaire daisy chain only Your system or console may require fewer luminaires on a single data link path Consult your conso...

Page 3: ...ware are required Many compatible truss hooks are available from different manufacturers for your particular needs A minimum of two hooks per luminaire is required If mounting method does not use truss hooks two attachment points per luminaire are required To install mounting hardware and brackets Step 1 Bolt each clamp to the Omega holder with screw and lock nut through the hole in the holder NOT...

Page 4: ...the inlet should be closest to the floor and the exhaust should be towards the ceiling This eliminates the possibility of one luminaire blowing exhaust air into the inlet of the luminaire next to it when the luminaires are side by side If the luminaires are stacked on top of one another in a side hang a 45 enclosure orientation with the fan inlet closest to the floor MENU OPERATION LCD DISPLAY AND M...

Page 5: ...ddress DMX Address appears Press Enter Step 3 Use Up Down arrow buttons to select the desired digit Step 4 Once all digits are set in DMX address press Enter to set Step 5 DMX displays and is saved STATUS BAR The Status Bar is present at all times and displays luminaire operational information of the luminaire The Status Bar contains the following information LED indicates current LED state ON or ...

Page 6: ...nter Up Lamp On Enter Down Lamp Off Up Down Display Invert QUICK REFERENCE DMX MAP DMX DESCRIPTION DMX DESCRIPTION 1 Intensity High 12 Blue High 2 Intensity Low 13 Blue low 3 Pan High 14 White High 4 Pan Low 15 White low 5 Tilt High 16 Color Preset 6 Tilt Low 17 Strobe Speed 7 Zoom 18 Strobe Control 8 Red High 19 Focus Timing 9 Red Low 20 Optics Timing 10 Green High 21 Color Timing 11 Green low 22...

Page 7: ...inspect unit for damage from shipping Installation and operation to be performed by qualified personnel only Use safety tether when mounting Install only in locations with adequate ventilation of at least 50cm clearance from adjacent surfaces Ensure sure that ventilation slots are not blocked Ensure that the voltage and frequency of the power supply match the power requirements of the fixture The fix...

Reviews: