4

VL800 EVENTWASH   

QUICK START GUIDE

To install in truss:

Step 1. 

Lift luminaire into mounting position.

Step 2. 

Secure in place with clamp handle. Ensure clamp handle hardware that Quick-lock fastener hook in 
place (e.g.. wing bolt) is properly tightened and that luminaire is fully supported.

Step 3. 

Attach safety cable (as required) as follows:

a. 

Loop safety cable at least once around safety cable anchor point rod.

b. 

Loop safety cable at least once around truss/pipe and secure around pipe.

SAFETY CABLE:

 Recommended for hanging installations. May be required by local codes. Safety cable is sold 

separately.

NOTE:

 Truss hooks shown are sold separately. Truss and pipe by others.

Step 4. 

Make sure hanger is disengaged so luminaire moves freely.

Step 5. 

Connect power and data cables according to procedure given in 

Connecting Data on page 2

.

When hanging the luminaire in a side hang position, natural convection and the designed direction of the inlet 
and exhaust cooling fans dictate that the inlet should be closest to the fl oor and the exhaust should be towards 
the ceiling. This eliminates the possibility of one luminaire blowing exhaust air into the inlet of the luminaire next 
to it when the luminaires are side-by-side.

If the luminaires are stacked on top of one another in a side hang, a 45° enclosure orientation with the fan inlet 
closest to the fl oor.

MENU OPERATION

LCD DISPLAY AND MENU SYSTEM

The VL800 Eventwash Luminaire’s LCD Display and Menu System provide local control for accessing the follow-
ing fi xture’s settings: 

•  Address – to set the DMX address

•  

Confi gure – various parameter settings, set LED, movement, display, reset defaults

•  

DMX – change the map, set address,

•  

Fixture – fi xture status, ReCal, reboot, software version, view fi xtures hours, crossload, service

•  

Test – to test functions of parameters

•  

Manual – to set the intensity, all functions

The menu system is controlled at the Menu Display available at the enclosure input panel. If there are multiple 
luminaires in a system, any settings or changes would need to be made at each LCD Menu as desired.

Safety Cable Anchor Point

NOTE:

 The safety cable anchor point

is tested and is in compliance with

IEC / EN 60598-1:2015

Summary of Contents for EVENTWASH VL800

Page 1: ...Current required depends on the AC supply voltage and product model NOTE The mating power connector is supplied however you will need to purchase or construct a cable ap propriate for your application FIGURE 1 POWER CONNECTOR Depending on the application the luminaire s AC input cable may require a different connector If required install a new connector meeting your requirements using the included...

Page 2: ...AGE AT 60HZ TOTAL LUMINAIRE CURRENT MOTOR LED CURRENT 100V 3 03A 110V 2 74A 120V 2 54A 130V 2 30A 200V 1 49A 210V 1 4A 220V 1 36A 230V 1 31A 240V 1 25A CONNECTING DATA A maximum of 32 luminaires may be connected in any one DMX data link NOTE This maximum limit applies to the luminaire daisy chain only Your system or console may require fewer luminaires on a single data link path Consult your conso...

Page 3: ...ware are required Many compatible truss hooks are available from different manufacturers for your particular needs A minimum of two hooks per luminaire is required If mounting method does not use truss hooks two attachment points per luminaire are required To install mounting hardware and brackets Step 1 Bolt each clamp to the Omega holder with screw and lock nut through the hole in the holder NOT...

Page 4: ...the inlet should be closest to the floor and the exhaust should be towards the ceiling This eliminates the possibility of one luminaire blowing exhaust air into the inlet of the luminaire next to it when the luminaires are side by side If the luminaires are stacked on top of one another in a side hang a 45 enclosure orientation with the fan inlet closest to the floor MENU OPERATION LCD DISPLAY AND M...

Page 5: ...ddress DMX Address appears Press Enter Step 3 Use Up Down arrow buttons to select the desired digit Step 4 Once all digits are set in DMX address press Enter to set Step 5 DMX displays and is saved STATUS BAR The Status Bar is present at all times and displays luminaire operational information of the luminaire The Status Bar contains the following information LED indicates current LED state ON or ...

Page 6: ...nter Up Lamp On Enter Down Lamp Off Up Down Display Invert QUICK REFERENCE DMX MAP DMX DESCRIPTION DMX DESCRIPTION 1 Intensity High 12 Blue High 2 Intensity Low 13 Blue low 3 Pan High 14 White High 4 Pan Low 15 White low 5 Tilt High 16 Color Preset 6 Tilt Low 17 Strobe Speed 7 Zoom 18 Strobe Control 8 Red High 19 Focus Timing 9 Red Low 20 Optics Timing 10 Green High 21 Color Timing 11 Green low 22...

Page 7: ...inspect unit for damage from shipping Installation and operation to be performed by qualified personnel only Use safety tether when mounting Install only in locations with adequate ventilation of at least 50cm clearance from adjacent surfaces Ensure sure that ventilation slots are not blocked Ensure that the voltage and frequency of the power supply match the power requirements of the fixture The fix...

Reviews: