Failure Isolation
4.1
Failure Isolation
To avoid problems with the Power Source, keep the tubing exterior and sealing head
clean and dry at all times.
If the system fails to operate properly, connect a different sealing head and RF power
cable to the Power Source to isolate the failed component.
If the Power Source performs properly, then the sealing head is suspected. If the Power
Source fails to function properly, then the Power Source
may
be the cause of malfunction.
In any event, contact your nearest Vante
™
authorized service representative or Vante
™
for
evaluation and repair.
4.2
Fuse Replacement
If the unit is plugged into an AC Power Source, and the RF Ready light is not illuminated
when the switch is in the
"
|
"
(on) position, then the fuse
may
need replacement.
Turn the AC power switch to the
"
"
(off) position and disconnect the AC power cord
from the AC outlet and Power Source.
Release the fuse holder slide latch by inserting the end of a flat blade screwdriver into the
detent as shown in Figure 4.1. Pull the fuse holder slide out until it stops and the fuse is
exposed.