background image

PURE BREEZE FUME HOOD

120V

25799 Jefferson Ave.

  

  

Murrieta, CA 92562

 

  

1-800-VANIMAN (826-4626)

  

  

www.vaniman.com

  

 

 

[email protected]

10370-11/21 PAGE 1

Page 1

Warnings and Precautions

 

 

This air purifier is designed to run on 120 volt alternating current at 60 Hz, 

with a maximum current of 5 amps at temperatures ranging from -10⁰C to +40⁰C 

(14⁰F to 104⁰F). The plug on the unit labeled “Power Cord ~” is for the supply line 

cord provided. The supply outlet in the wall must have a wired ground and if the 

door of the unit is opened for any reason, do not bypass the protective earthing.  

 

When choosing the location of your Pure Breeze Fume Hood, be sure that 

the location allows the power cord to be accessible at all times. Additionally, since 

the Pure Breeze Fume Hood draws air into the unit from the bottom and exhausts 

clean air from the side, ensure that the unit is either mounted to the wall or ceiling 

and there is at least 6 inches of clearance near the exhaust openings on the side 

of the unit. A lack of airflow through the unit will decrease the efficiency of the air 

purification process.

 

Failure  to  comply  with  the  precautions  listed  here  or  any  others  for  this 

equipment may cause electrical shock or equipment failure. 

-Alternating Current

-Caution, Risk of Electrical Shock

Pure Breeze Fume Hood

PN: 10370

Dimensions: 

37.8”L x 24.8”W x 20.3”H

Weight: 

70 lbs.

Voltage: 

120V

Amperage: 

5A

Frequency: 

60Hz.

Power Rating: 

204W

 20.3 

 37.8 

 24.8 

Front View

Top View

Summary of Contents for VMC-A450

Page 1: ...Hood be sure that the location allows the power cord to be accessible at all times Additionally since the Pure Breeze Fume Hood draws air into the unit from the bottom and exhausts clean air from the...

Page 2: ...2 Laying the Fume Hood flat with the control panel facing up unlatch the door from the left side and open Remove all filters from the unit and remove the plastic bags covering each filter The plastic...

Page 3: ...each side for proper exhausting ventilation and access to the door latches i One piece of the bracket is mounted on the back of the unit at the factory ii Mount the second bracket piece with the open...

Page 4: ...he selector switch on the bottom of the unit to either low medium or high 6 If you are using Vaniman s Remote Switch accessory P N VMC A450 test it with the Fume Hood by plugging it into the socket la...

Page 5: ...filters and replace them in the opposite order then they were removed Order P N 97021 b The Secondary Filter is identified by its white media and is the second filter from the bottom in the stack This...

Page 6: ...the On Off switch into the Off position unplug the power cord from the unit correct the problem then push the breaker reset button until it clicks 2 Thermal Protection The motor in the unit is protect...

Page 7: ...vice disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to service the panel c When servicing or replacing components unplug the power cord to ensure that th...

Reviews: