Trinocular Port

Set Screw

Reflected

Illumination

Analyzer Knob

Reflected

Illumination

Polarizer Slider

Diaphragm

Centering

Adjustment

(right)

X-Axis Lamp

Adjustment

Knob

Lamp

Housing

Door

Y-Axis Lamp

Adjustment

Knob

Lamp Housing

Power Cord

and Plug

Stage Limit

Main Power

Jack

Fuse Holder

Variable
Lighting

Control

Y-Axis
Stage

Control

Z-Axis
Stage

Control

Drop-In Colored
Filter Holder

Swing-In
Condenser Lens

Objectives

Head

Reflected
Illuminator

Reflected
Illuminator
Set Screw

T

T

T

T

Troubleshooting

roubleshooting

roubleshooting

roubleshooting

roubleshooting

24

This chart may help resolve some of the more common problems associated
with using a compound microscope.  Simply follow the steps until your problem
is resolved.  As always, you can  contact your dealer or VanGuard Microscopes
if you ever need help.

For information about parts, accessories, or service -- contact your dealer directly
or contact VanGuard Microscopes at 1-800-423-8842.

 Symptom:

No light visable from reflected (upper) illuminator

Step #

Possible Cause

How To Test

Test Result?

Solution

For More Info

1

7

6

5

4

3

Light is not switched on

Visually inspect

Switched on

Not switched on

Go to next step

Move power switch to on position

Page 12

Main power cord and/or illuminator
plug not connected

Visually inspect

Plugged in

Not plugged in

Go to next step

Plug in power cord or illuminator plug

Variable lighting control (VLC)
turned all the way down

Visually inspect

VLC turned up

VLC turned down

Go to next step

Turn VLC up

Page 16

Microscope not getting power

Inspect  outlet

Good outlet

Outlet not good

Go to next step

Plug power cord into working outlet

Blown fuse

Visually inspect or try new fuse

Good fuse

Fuse is blown

Go to next step

Install new fuse

Page 22

Burnt out lamp

Visually inspect or try new lamp

Good lamp

Lamp is burnt out

Contact dealer or VanGuard Microscopes

Install new lamp

Page 21

2

Illumination selector switch is not
set to the “UP” position

Visually inspect

Set to “UP”

Set to “DOWN”

Go to next step

Switch the selector to “UP”

Page 12

Page 11

Page 11

 Symptom:

No light visable from transmitted (lower) illuminator

Step #

Possible Cause

How To Test

Test Result?

Solution

For More Info

1

7

6

5

4

3

Light is not switched on

Visually inspect

Switched on

Not switched on

Go to next step

Move power switch to on position

Page 16

Main power cord and/or illuminator
plug not connected

Visually inspect

Plugged in

Not plugged in

Go to next step

Plug in power cord or illuminator plug

Variable lighting control (VLC)
turned all the way down

Visually inspect

VLC turned up

VLC turned down

Go to next step

Turn VLC up

Page 16

Microscope not getting power

Inspect  outlet

Good outlet

Outlet not good

Go to next step

Plug power cord into working outlet

Blown fuse

Visually inspect or try new fuse

Good fuse

Fuse is blown

Go to next step

Install new fuse

Page 22

Burnt out lamp

Visually inspect or try new lamp

Good lamp

Lamp is burnt out

Contact dealer or VanGuard Microscopes

Install new lamp

Page 21

2

Illumination selector switch is not
set to the “Down” position

Visually inspect

Set to “Down”

Set to “Up”

Go to next step

Switch the selector to “Down”

Page 16

Page 11

Page 11

Brightfield Abbe
Condenser

Summary of Contents for 1442MMi

Page 1: ...Printed in the USA VGMNL062512 1400MMi Operation Manual Model 1442MMi www veegee com 800 423 8842 sales veegee com support veegee com...

Page 2: ...croscope system Modifying the product in any manner for use not originally intended shall automatically void the manufacturer s warranty In no event shall VEE GEE Scientific Inc be held liable for any...

Page 3: ...surfaces are made Shock Hazard failure to follow instructions could lead to electrical shock Safety Precautions Before replacing the lamp or fuses always turn off the power switch and disconnect the p...

Page 4: ...ymptom Image through eyepieces is too dim Step Possible Cause HowToTest TestResult Solution For More Info 1 2 Variable lighting control VLC is turned down too far Visually inspect VLC is turned up VLC...

Page 5: ...turned down Go to next step Turn VLC up Page16 Microscope not getting power Inspect outlet Good outlet Outlet not good Go to next step Plug power cord into working outlet Blown fuse Visually inspect...

Page 6: ...an to prevent contaminate ingress is essential to the longevity of the objectives All other parts can be cleaned with a paper towel and mild detergent It s not recommended to use rubbing alcohol for c...

Page 7: ...eplacement Fuse 3A 250V Cat No 1400 FS5 If the microscope is plugged in but the illuminator is not turning on the fuse could be blown The instructions below detail how to check for a blown fuse You ca...

Page 8: ...resistance do not force 4 Close the compartment door and follow the instructions in the Reflected Illumination Setup section to properly center the lamp Replacing the Reflected Illuminator Lamp Replac...

Page 9: ...lyzer knob located on the right side of the reflected illuminator must be pushed inward to engage this function figure 55 1 Carefully remove all components from foam packaging and plastic bags Use the...

Page 10: ...ve In addition you will need to fully open the aperture iris in order to prevent vignetting and leave the condenser height the same as when originally setup using the 10X objective 5 To control contra...

Page 11: ...er installed but should you need to reinstall at any point follow the directions below 13 Rotate the nosepiece so that either the 5X objective or an empty slot is in the light path 14 Using the coarse...

Page 12: ...making adjustments to the illuminator housing or lamp fixture 3 Ensure that the illumination selector knob is pushed all the way inward R figure 17 Figure 15 Figure 17 Figure 18 Figure 19 4 Rotate the...

Page 13: ...b adjusts for latitudinal X axis and the lower for longitudinal Y axis movement figure 21 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 10 Rotate each of these in succession until the field of vie...

Page 14: ...and should be checked and readjusted before each use Focus Adjustment 18 Focusing on your specimen is achieved through rotating the coarse and or fine focusing knobs These are located on either side o...

Reviews: