background image

Components

Components

Components

Components

Components

4

Lamp Housing

Lamp Focus
Knob

Eyepieces

with

Eyecups

Trinocular Port

Dust Cap

Trinocular Port

Diaphragm
Centering
Adjustment
(left)

Head Set
Screw

Prism Selector

Knob

Illumination

Selector Knob

Diopter

Adjustment

Objective

Turret

Mechanical
Stage

Substage
Control

Fine Focus
Control

Coarse

Focus

Control

Focus

Tension

Control

Power

Switch

Illumination

Selector Switch

Base

Transmitted Illumination

Aperture Diaphragm

Glass Stage Insert

Transmitted Illumination

Field Diaphragm

T

T

T

T

Troubleshooting

roubleshooting

roubleshooting

roubleshooting

roubleshooting

25

For information about parts, accessories, or service -- contact your dealer directly
or contact VanGuard Microscopes at 1-800-423-8842.

 Symptom:

Can’t focus on specimen image

Step #

Possible Cause

How To Test

Test Result?

Solution

For More Info

2

1

Dirty objective

Visually inspect

Objective is clean

Objective is not clean

Go to next step

Clean objective or replace with new objective

Page 23

Stage limit set too low

Check position of stage limit by
loosening the control and adjusting
the focus

Stage limit set correctly

Set too low

Contact dealer or VanGuard Microscopes

Raise stage and set stage limit

Page 15

 Symptom:

The stage keeps drifting downward

Step #

Possible Cause

How To Test

Test Result?

Solution

For More Info

1

Focus tension is set too loose

  

Check focus tension control

  

Tension too loose

  

Tension set correctly

  

Increase tension

  

Contact dealer or VanGuard Microscopes

  

Page 15

Stand

 Symptom:

Image through eyepieces is too dim

Step #

Possible Cause

How To Test

Test Result?

Solution

For More Info

1

2

Variable lighting control (VLC) is
turned down too far

  

Visually inspect

  

VLC is turned up

  

VLC is turned down

  

Go to next step

  

Turn VLC up

  

Page 12, 16

Lamp not centered properly

  

Visually inspect

  

Lamp is centered

  

Lamp is not centered

  

Go to next step

  

Center the lamp

  

Page 13, 17

3

Dirty condenser, eyepiece, or
objective lenses

  

Visually inspect

  

Lenses are dirty

  

Lenses are clean

  

Clean condenser, eyepiece, or objective lenses

  

Contact dealer or VanGuard Microscopes

  

Page 23

 Symptom:

No image visable in eyepiece and/or trinocular port

Step #

Possible Cause

How To Test

Test Result?

Solution

For More Info

1

6

4

3

2

Light is not switched on

Visually inspect

Switched on

Not switched on

Go to next step

Move power switch to on position

Page 12, 16

Variable lighting control (VLC) is set
too low

Visually inspect

Not set too low

Set too low

Go to next step

Increase VLC level

Objectives not installed or turret is
set to empty position

Visually inspect

Objectives are installed

Objectives not installed

Go to next step

Install objectives or change turret position

Page 10

Prism selector knob in wrong
position

Visually inspect

In correct position

Not in correct position

Go to next step

Set to correct position

Page 11

Light path blocked (transmitted
illumination)

Visually inspect space between
illuminator and objectives

Blockage present

Nothing blocking

Remove blockage

Contact dealer or VanGuard Microscopes

Page 18

Page 12, 16

5

Illumination selector switch and/or
knob are set at incorrect positions

Visually inspect

In correct position

Not in correct position

Go to next step

Set to correct position

Page 12, 16

Summary of Contents for 1442MMi

Page 1: ...Printed in the USA VGMNL062512 1400MMi Operation Manual Model 1442MMi www veegee com 800 423 8842 sales veegee com support veegee com...

Page 2: ...croscope system Modifying the product in any manner for use not originally intended shall automatically void the manufacturer s warranty In no event shall VEE GEE Scientific Inc be held liable for any...

Page 3: ...surfaces are made Shock Hazard failure to follow instructions could lead to electrical shock Safety Precautions Before replacing the lamp or fuses always turn off the power switch and disconnect the p...

Page 4: ...ymptom Image through eyepieces is too dim Step Possible Cause HowToTest TestResult Solution For More Info 1 2 Variable lighting control VLC is turned down too far Visually inspect VLC is turned up VLC...

Page 5: ...turned down Go to next step Turn VLC up Page16 Microscope not getting power Inspect outlet Good outlet Outlet not good Go to next step Plug power cord into working outlet Blown fuse Visually inspect...

Page 6: ...an to prevent contaminate ingress is essential to the longevity of the objectives All other parts can be cleaned with a paper towel and mild detergent It s not recommended to use rubbing alcohol for c...

Page 7: ...eplacement Fuse 3A 250V Cat No 1400 FS5 If the microscope is plugged in but the illuminator is not turning on the fuse could be blown The instructions below detail how to check for a blown fuse You ca...

Page 8: ...resistance do not force 4 Close the compartment door and follow the instructions in the Reflected Illumination Setup section to properly center the lamp Replacing the Reflected Illuminator Lamp Replac...

Page 9: ...lyzer knob located on the right side of the reflected illuminator must be pushed inward to engage this function figure 55 1 Carefully remove all components from foam packaging and plastic bags Use the...

Page 10: ...ve In addition you will need to fully open the aperture iris in order to prevent vignetting and leave the condenser height the same as when originally setup using the 10X objective 5 To control contra...

Page 11: ...er installed but should you need to reinstall at any point follow the directions below 13 Rotate the nosepiece so that either the 5X objective or an empty slot is in the light path 14 Using the coarse...

Page 12: ...making adjustments to the illuminator housing or lamp fixture 3 Ensure that the illumination selector knob is pushed all the way inward R figure 17 Figure 15 Figure 17 Figure 18 Figure 19 4 Rotate the...

Page 13: ...b adjusts for latitudinal X axis and the lower for longitudinal Y axis movement figure 21 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 10 Rotate each of these in succession until the field of vie...

Page 14: ...and should be checked and readjusted before each use Focus Adjustment 18 Focusing on your specimen is achieved through rotating the coarse and or fine focusing knobs These are located on either side o...

Reviews: