AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 3: SPECIFICATIONS
090034-OP_r0
PAGE - 35
TABLE 3F: VARIOUS FUNCTION FACTORY SETTING RANGES
FUNCTION
FACTORY SETTING
Motor No-Load Hi RPM
3100
Air Cut-in pressure
100
Air Cut-out pressure
125
AC generator Hz (no load)
61
AC generator 240 plug (no load)
243
AC generator 120 plug (no load)
122
AC generator 120 plug (no load)
122
Welder OCV Voltage
70
Welder Max Amperage
300
Welder Max CV Voltage
40
Welder Min CV Voltage
15
Welder 12V charge voltage
14
Welder 12V boost voltage
16
Welder 24V boost voltage
30
TABLE 3G: GENUINE VANGUARD™ OIL CHARACTERISTICS
Viscosity
178 SUS at 100°F (38°C)
Flashpoint
495°F (257°C)
Pour point
-49°F (-45°C)
Contains
Rust and Oxidation Inhibitors
Contains
Detergents
TABLE 3H: MACHINE PACKAGE DIMENSIONS
For complete machine package dimensions, consult
Section 4.5 Installation and
Dimensions Diagram (Part 1 of 2)
, and
Section 4.6 Installation and Dimensions
Diagram (Part 2 of 2)
.