AIR N ARC 300
®
ALL-IN-ONE POWER SYSTEM
®
APPENDIX A: ADDITIONAL INFORMATION
090034-OP_r0
PAGE - 155
1. Hose is weakened when installed in twisted
position. Pressure in twisted hose tends to
loosen fitting connections. Design so that
machine motion produces bending rather than
twisting.
2. Ample bend radius should be provided to
avoid collapsing of line and restriction of flow.
3. Exceeding minimum bend radius will greatly
reduce hose assembly life.
4. Use elbows or other adapters as necessary to
eliminate excess hose length and to insure
neater installation for easier maintenance.
5. When hose assembly is installed in a flexing
application, remember that metal hose fittings
are not part of the flexible portion. Allow
ample free length for flexing.
6. When properly routing, use clamps to secure
the hose in its proper position.
A.6 HOSE INSTALLATION GUIDE