42
42
FAS-402 Series Operating Instructions Ver. 4.06E
Replace parts according to the following directions in order to maintain your machine in optimum operating
condition.
The sealing section is constructed with parts illustrated in the below diagram. When replacing parts, be careful to
arrange the parts in the same exact order.
As you use the sealer, the parts wear, sealing result worst., to continues operate with damage part will cause
malfunction, so please replace the wear parts on time with space parts always in hands.
The routine maintenance parts are selling by the unit described below
Order from your dealer, specifying the name of your machine, the name and quantity of parts you need.
Parts name
Sales unit
Heating element (5mm,10mm)
10 pcs. / set
Fluoro glass sheet
2 sheets / set
Silicone rubber
2 pcs. / set
Glass tape
5M roll or 10M roll
Sarcon sheet
2 sheets / set or 5M roll
Plastic nut (white)
5 pcs. / set
Center dry tape
5M roll
110V specification
220V specification
1
FAS-402 (single-side heating type)
2
FAS-402-10D (double-side heating type)
9 Replacing the routine maintenance parts
Construction of the sealing section
Routine maintenance parts
Always unplug power plug
from the wall outlet before
conducting any maintenance.
Warning
Warning
Warning
Always unplug power plug before replacing any parts. There is a danger of electrocution if
conducted with the plug still inserted.
Do not replace parts according to other methods not described in the operating instructions. It is
dangerous if incorrect methods are used.
When replacing parts, always use only specified parts sold through
Van der Stahl Scientific
.
Otherwise malfunction may occur.
Pressure lever
Silicone rubber
Fluoro glass sheet
Heating element
Glass tape 25mm
Sarcon sheet
Pressure lever
Silicone rubber
Glass tape 19mm
Heating element
Fluoro glass sheet
Heating element
Glass tape 25mm
Sarcon sheet
Glass tape 50mm
Glass tape 19mm
Center-dry tape
Temperature sensor
Temperature sensor