FAS-402 Series Operating Instructions Ver. 4.06E
This chapter explains how to register a new operation pattern with following two samples.
Please read this chapter thoroughly before start registering the other operation patterns.
Operation No.[05] SEALING ONLY
Operation setting:
Heating temperature 140ºC/280ºF , Heating time 0.3 seconds, Cooling temperature 100ºC/200ºF.
8-2-1 Sample case: how to register the
“seal only”
operation
8-2-2 Sample case: how to register the
“vacuum (timer) + seal”
operation
Operation No.[06] VAC&SEAL timer
Operation setting:
Heating temperature 140ºC/280ºF, Heating time 0.3 seconds, Cooling temperature 100ºC/200ºF
Vacuum time 12.0 sec.
8-2 Register sample operation patterns
Attention
Maximum 10 operation patterns can be stored in the microcomputer controller (control unit).
If you are going to register over 10 operation patterns, the message "Entry No' is full Please delete
an unnecessary entry No' " is displayed on the digital display.
You cannot input a new operation pattern until at least one of the stored operation patterns is
deleted.
Attention
The biggest number is automatically assigned to the new entry.
e.g.) If there are 4 operation numbers, the new entry becomes 05.