![Valor Ultimate Turbochim BR517R Installer'S Manual Download Page 16](http://html1.mh-extra.com/html/valor/ultimate-turbochim-br517r/ultimate-turbochim-br517r_installers-manual_3865043016.webp)
16
10)
6.1
Install a power supply at a switched fuse having a minimum separation
of 3mm at all poles. The spur should be readily accessible to the user, easily
identifiable and preferably sited adjacent to the appliance. It should only connect
this appliance.
6.2
To simplify installation of the cable supplied, it may be most convenient
to disconnect it from the appliance as described below, install it to the wall and
then reconnect to the appliance:
To disconnect the cable:
1)
Detach the burner (See section 4.3).
2)
Detach the control unit from the convection box left side flange by
removing two screws (see figure 10). Carefully pull the unit slightly
forward.
3)
Detach the fan wiring loom connection (See figure 11).
4)
Detach the plastic vacuum tube from the metal vacuum pipe (see
figure 11).
5)
Detach the control unit cover by removing one screw (See figure
12).
6)
Remove the cable by releasing the cable clamp and detaching the
three leads.
6.3
When installing the cable, leave a minimum of 200mm of the
cable slack at the cable clamp end to allow installation of the appliance after
reconnection to the control box and to allow future removal of the control
box for servicing.
6.4
If the spur is at the right side of the appliance, run the cable under
the hearth.
The cable must not run directly under or behind the appliance.
Figure 12 Control cover fixing
Figure 11 Fan loom & vacuum
pipe connections
P A R T 6 :
E L E C T R I C A L I N S T A L L A T I O N
Figure 10 Electrical control
unit fixings