6
Approval & Codes
This appliance is certi
fi
ed to ANSI Z21.88/CSA 2.33
American National Standard / CSA Standard for Vented
Gas Fireplace Heaters for use in Canada and USA, and
to CGA 2.17-M91 High Altitude Standard in Canada.
This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual
fi
replace e
ffi
ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Natural Gas and
Propane Installation Code CAN/CGA-B149.1. Only
quali
fi
ed licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certi
fi
ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to con
fi
rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Model
530IN
530IP
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
20,500
19,000
Input Minimum (Btu/h)
6,500
12,500
Manifold Pressure (in w.c.)
3.5–3.9”
10.3–10.7”
Minimum Supply Pressure (in w.c.)
5”
11”
Maximum Supply Pressure (in w.c.)
10.5”
14”
Main Burner Injector Marking
580
200
Pilot Injector Marking
35
27
Min. Rate By-Pass Screw
125
125
Supply Gas
Heater engine 530IN is used with natural gas.
Heater engine 530IP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings table.
The supply connection is 3/8” NPT female located at the
left side of the control valve. The opening for the gas
supply line is at the rear left corner of the appliance.
Gas Conversion
The 530
fi
replace is o
ff
ered with natural gas or propane
gas. It can be converted from one gas to the other. See
installation manual supplied with the gas conversion kit
for more information.
Fuel Beds
The 530 engine can use a simulated logs, coals, rocks or
driftwood fuel bed with natural gas or propane.
Electrical
The 530 does not require an electrical power source
unless
fi
tted with an optional circulating fan.
Specifications
Gas supply
connection 3/8”
NPT female at
valve
Gas line access at
rear left corner
WARNING
Optional electrical accessories ARE NOT
ALLOWED when adapting appliance for
outdoor use.