25
Front & Top Installation
Front Installation
Hook the cast front to the side brackets located
between the engine and the cast sides.
Cast front
Hook
Details
Engine
Side bracket
Air Shutter
Operation Check
Turn the
fi
replace
fl
ame up and down using the
remote control to con
fi
rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 30–34.
Aeration Settings
Light the
fi
re and allow the unit to warm up for 10–15
minutes to evaluate the
fl
ame picture. The burner
is equipped with an adjustable shutter to control
primary aeration. See the
fi
gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Operation Check & Aeration Settings Adjustment
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Open
Close
LPG
Open
Open
Close
Close
NG
NG Air Shutter
Slider & Cover
In a few unusual installations, the
fl
ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic logs and window installed.
Increasing aeration
will cause the
fl
ames to appear
more transparent and blue making the ceramic logs
glow more.
Decreasing aeration
will cause the
fl
ames to appear
more yellow or orange making the ceramic logs glow less.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
INSTALLATION