of the handset. Momentarily pressing and releasing the SET button advances through
the settable features and pressing and releasing the MENU button returns to the
previous one. Pr or – changes the displayed information, for example :-
o H 24 – This is the 12 hr or 24 hours time format. Pressing and releasing + or – will
change H24 into H12. Once happy with that setting, press and release SET to move
to the day of the week.
o Day of the week is Mo, Tu, We,Th,Fr, Sa, Su. Again pressing and rel/- will
change the day and when happy press and release SET to move to the hour of the
day.(Pressing Mode button
-
Within the subsequent 20 seconds press the ‘DOWN’ button on the handset until
you hear an additional long signal confirming the code is set
NOTE:
Please inform the customer that this is a one time setting and is NOT required
when changing batteries in the handset or battery box.
10.7 Factory reset of handset
As stated in 10.6 the remote reciever is already linked, but in the event it is needed to
reset the remote reciever back to factory reset, “breaking all links to the valve” follow
these steps;
Activate the handset, then press and hold SET until SETUP is flashing. Keep
pressing SET until CA0 appears on the screen, use + or – to change to CA1. Then
press SET.
The handset should now read TESC r5 (7ESC r5), and is ready to be paired with the
valve.
10.8 Checking the ignition operation.
-
Picking up and holding the handset will unlock the
keypad and the green light will illuminate a solid green.
- Press and hold the ‘ON’ power button ( approx 1 - 2
seconds), then release as soon as the word “PILOT”
appears at the bottom left of the display this confirms the
start sequence has begun.
-
There will be a slight delay and several sparks should
be seen between the electrode and pilot tip.
-
On sensing a flame is not present the burner unit will
shut off. If there are no sparks check the following:
-
Ensure that the electrode lead is connected to the terminal at the base of the
electrode. If the above is correct, check for damage to the electrode lead and that the
batteries have been correctly fitted.
10.9 Error codes
During the setup process Error codes could be generated on the handset (i.e. E00).
These can be reset/cleared by;
Activate the handset, then press and hold ‘ON’ power button continously for 3 - 5
seconds. If the errors repeat first ensure brand new Alkaline batteries are fitted into
the remote control and valve as low powered batteries can generate different error
codes. Failing that please contact our customer service for further asistance.