Valor HORIZON 535 Installation Booklet Download Page 4

3 of 23  

2.

 

OPTIONS 

Heater engine unit #535EAN is used with all natural gas 
installations. 
Heater engine unit #535EAP is used with all propane 
installations. 
 

2.1.

 

Appliance styles 

Standard metal front. Black – 

Kit #601SFB

  

Cast iron front.  Black   –    

Kit #602CFB. 

One of the above kits must be used with each 
installation. 

2.2.

 

Optional outer trims 

3 sided Black     –       

Kit #603FSK 

3 sided Champagne – 

Kit# 604FSK 

4 sided Black     –       

Kit #605FSK 

4 sided Champagne – 

Kit# 606FSK 

 

2.3.

 

Additional optional features 

Remote control unit 

Hand operated control for 
flame & heat adjustment. It 
may be fitted before the 
fireplace is installed or 
retrofitted at a later date - 

   

Kit #553RCK. 

Circulating fan 

Having variable speed and 
temperature control, it is 
designed to boost the natural 
convection process through the 
appliance. It may be fitted 
before the fireplace is installed 
or retrofitted at a later date –  

Kit #555CFK

Wall switch extension 

Optional 10ft. long wire kit that 
enables the switch to be sited 
on a wall further away from the 
appliance than the standard 
switch. The standard switch has 
4ft. of wire.  

 

Kit #609WEK 

Natural Gas  

For conversion from propane to

 

Conversion kit 

natural gas – 

Kit #608NGK

 

Intended primarily for post 
installation conversion in areas 
where natural gas was not 
available at the time of initial 
installation.  

2.4.

 

Venting options 

2.4.1.

 

Direct vent installations 

One or more of the accessories listed below must be used 
for each installation. See the “Location” section of this 
manual. 

Kit#

 

551DVK 

Valor horizontal terminal kit provides up 
to 26” (66cm) horizontal run. Complete 
with wall plates and clearance shield 
approved for a maximum 14” (36cm) 
combustible wall. 

817VAK 

Adapter for Dura-vent pipes 

984 

Dura-vent DV GS horizontal square 
terminal cap 

942 

Dura-vent DV GS wall thimble kit 

945B 

45° Dura-vent DV GS elbow 

990B 

90° Dura-vent DV GS elbow 

908B 

6” Dura-vent DV GS pipe length 

907B 

9” Dura-vent DV GS pipe length 

906B 

12” Dura-vent DV GS pipe length 

904B 

24” Dura-vent DV GS pipe length 

903B 

36” Dura-vent DV GS pipe length 

902B  

48” Dura-vent DV GS pipe length 

911B 

Adjustable 11”-14

5

/

8

” Dura-vent DV GS 

pipe length 

981 

Dura-vent DV GS snorkel termination 
unit – 36” rise 

982 

Dura-vent DV GS snorkel termination 
unit – 14” rise 

991 

Dura-vent DV GS high wind vertical 
termination cap 

940 

Dura-vent DV GS round ceiling support 

941 

Dura-vent DV GS cathedral ceiling 
support box 

963 

Dura-vent DV GS ceiling firestop 

943 

Dura-vent DV GS adjustable roof 
flashing. Roof pitch 0/12 – 6/12 

943S 

Dura-vent DV GS steep roof flashing. 
Roof pitch 7/12 – 12/12 

953 

Dura-vent DV GS storm collar 

988 

Dura-vent DV GS wall strap 

835TG 

Terminal Guard 

 

Summary of Contents for HORIZON 535

Page 1: ...lothes etc This appliance is suitable for installation in a bedroom or bed sitting room WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing...

Page 2: ...off Fitting 14 7 6 Support Angle Fitting 14 7 7 Attaching Air Restrictors 15 7 8 Attaching Rear Ceramic Support 15 7 9 Attaching to the Framing 15 8 INSTALLATIONS WITH HORIZONTAL TERMINATION INSTALLI...

Page 3: ...ther flammable vapors and liquids Never attempt to burn paper or any other material in the appliance The venting terminal must not be recessed into a wall or siding The vent terminal on the outside wa...

Page 4: ...ersion in areas where natural gas was not available at the time of initial installation 2 4 Venting options 2 4 1 Direct vent installations One or more of the accessories listed below must be used for...

Page 5: ...rance B 7 178mm 8 203mm 9 229mm 10 254mm 11 279mm 12 305mm 14 356mm Figure 1 Major dimensions clearances without optional trims Shown with 601SFB Front 3 sided trims 4 sided trims Figure 2 601SFB Fron...

Page 6: ...s These appliances when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrica...

Page 7: ...ombustible hearth is not necessary in front of this appliance All combustible materials must be outside the dimensions shown in figure 4 Be aware of the area 9 x 35 23cm x 90 2cm immediately above the...

Page 8: ...materials above horizontal pipe run inside building Outside wall shields thimbles 5 12 7cm G Clearance to combustible materials below horizontal pipe run 15 16 3 3cm H Clearance to combustible materi...

Page 9: ...ination The dimensional requirements in sections 4 2 and 4 3 apply Adapter 817VAK one 90 vent elbow 990B and Dura vent pipe lengths will be required 942 Dura vent thimble kit may also be necessary See...

Page 10: ...l straps a vertical vent terminal roof flashing and Dura vent pipe lengths will be required Various other ceiling or roof items may be necessary depending on the particular installation See venting op...

Page 11: ...on on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Clearance to unventila...

Page 12: ...fixing appliance to studding 601SFB Standard metal front Alternative 1 Upper louver unit 1 Lower louver unit 2 Side channels 2 Hinge studs 2 Hinge spacers 2 Magnet counterplates 602CFB Cast iron fron...

Page 13: ...12 of 23 Figure 11 Pack contents...

Page 14: ...er clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield See figure 13 7 3 Flame Control Motor Check See figure 14 Fit the battery...

Page 15: ...he shield to the case sides by refitting the two screws at the top rear corners and by two screws from the pack fitted near the front Bend the two top rear stand offs and fit to the heat shield with t...

Page 16: ...l rise of 3ft or more fit the restrictors at maximum port opening position See Graph 2 On models 535 the horizontal type restrictors are never set at any position except maximum port opening 7 7 2 Ins...

Page 17: ...de of the wall plates with 6 thread cutting screws per plate See figure 22 2 Bend the inner wall plate tab as shown in figure 23 so that the seam on the terminal tube will pass clearly through the pla...

Page 18: ...pass through the roof If directly above the position where it penetrates the ceiling drop a plumb from the roof to the small hole in the ceiling and mark the roof at this spot If rafters or other obst...

Page 19: ...ning at the bottom right side of the heater case Cut off the L terminals from the switch wires on the remote control receiver and remove insulation from approximately at ends of wires See figure 30 Se...

Page 20: ...gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5kPa f Failure to ei...

Page 21: ...tely behind the burner See figure 39 2 Place the rear log in position locating the two top projections in the ash bed into the holes in the rear log See figure 40 3 Place the two front logs at the fro...

Page 22: ...l other controls wall switch remote hand unit See owner s lighting instructions further on in this manual for full details Aeration adjustment As described in section 11 for natural gas appliances the...

Page 23: ...e two adhesive backed magnet counterplates to the tabs at the firebox sides which line up with the magnets on the lower louver See figure 48 Fit the two side channels by hooking into the openings at t...

Page 24: ...ar clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force 4 Wait five 5 minutes to clear out...

Reviews: