![Valor HORIZON 535 Installation Booklet Download Page 4](http://html1.mh-extra.com/html/valor/horizon-535/horizon-535_installation-booklet_3656764004.webp)
3 of 23
2.
OPTIONS
Heater engine unit #535EAN is used with all natural gas
installations.
Heater engine unit #535EAP is used with all propane
installations.
2.1.
Appliance styles
Standard metal front. Black –
Kit #601SFB
Cast iron front. Black –
Kit #602CFB.
One of the above kits must be used with each
installation.
2.2.
Optional outer trims
3 sided Black –
Kit #603FSK
3 sided Champagne –
Kit# 604FSK
4 sided Black –
Kit #605FSK
4 sided Champagne –
Kit# 606FSK
2.3.
Additional optional features
Remote control unit
Hand operated control for
flame & heat adjustment. It
may be fitted before the
fireplace is installed or
retrofitted at a later date -
Kit #553RCK.
Circulating fan
Having variable speed and
temperature control, it is
designed to boost the natural
convection process through the
appliance. It may be fitted
before the fireplace is installed
or retrofitted at a later date –
Kit #555CFK
.
Wall switch extension
Optional 10ft. long wire kit that
enables the switch to be sited
on a wall further away from the
appliance than the standard
switch. The standard switch has
4ft. of wire.
Kit #609WEK
Natural Gas
For conversion from propane to
Conversion kit
natural gas –
Kit #608NGK
.
Intended primarily for post
installation conversion in areas
where natural gas was not
available at the time of initial
installation.
2.4.
Venting options
2.4.1.
Direct vent installations
One or more of the accessories listed below must be used
for each installation. See the “Location” section of this
manual.
Kit#
551DVK
Valor horizontal terminal kit provides up
to 26” (66cm) horizontal run. Complete
with wall plates and clearance shield
approved for a maximum 14” (36cm)
combustible wall.
817VAK
Adapter for Dura-vent pipes
984
Dura-vent DV GS horizontal square
terminal cap
942
Dura-vent DV GS wall thimble kit
945B
45° Dura-vent DV GS elbow
990B
90° Dura-vent DV GS elbow
908B
6” Dura-vent DV GS pipe length
907B
9” Dura-vent DV GS pipe length
906B
12” Dura-vent DV GS pipe length
904B
24” Dura-vent DV GS pipe length
903B
36” Dura-vent DV GS pipe length
902B
48” Dura-vent DV GS pipe length
911B
Adjustable 11”-14
5
/
8
” Dura-vent DV GS
pipe length
981
Dura-vent DV GS snorkel termination
unit – 36” rise
982
Dura-vent DV GS snorkel termination
unit – 14” rise
991
Dura-vent DV GS high wind vertical
termination cap
940
Dura-vent DV GS round ceiling support
941
Dura-vent DV GS cathedral ceiling
support box
963
Dura-vent DV GS ceiling firestop
943
Dura-vent DV GS adjustable roof
flashing. Roof pitch 0/12 – 6/12
943S
Dura-vent DV GS steep roof flashing.
Roof pitch 7/12 – 12/12
953
Dura-vent DV GS storm collar
988
Dura-vent DV GS wall strap
835TG
Terminal Guard