![Valor HORIZON 534JN Installation & Owner'S Manual Download Page 32](http://html1.mh-extra.com/html/valor/horizon-534jn/horizon-534jn_installation-and-owners-manual_3647126032.webp)
32
Install Top Heat Shield & Stand-off s
1. If installing appliance with top vent outlet
,
remove the plate covering the vent hole in the top
heat shield by unscrewing four screws.
If installing
with rear vent outlet, the plate must remain to
cover the hole.
2. Remove the screws at the top rear corner of the
case sides.
3. If top vent outlet, locate the heat shield over the vent
pipe adapter.
4. Support the front of the shield on the two angle
supports.
5. Secure the shield to the case sides by refi tting
the two screws at the top rear corners and by two
screws from the pack fi tted near the front.
6. Bend the two top rear stand-off s and fi t to the heat
shield with three screws each.
NOTE:
Zero clearance stand-off s and shield supplied
with the heater are
not required for the co-linear
application
.
Install Support Angles
The distance from the wall angles to the front face of
the heater case is adjustable between 3/8 inch (10 mm)
and 1-3/16 inch (30 mm) to allow for a range of wall
fi nish material thickness (e.g. tile, etc.).
NOTE: When adding optional fronts and trims, it is
important to install heater
fl
ush or slightly recessed into
the
fi
nished
wall surface.
1. Fit the top angle support to the case top (3 screws).
2. Fit the two side angle supports (2 screws each). Fit
the screws from inside the heater case.
Remove Rear Log Support
Remove the rear log support to access to the rear
orifi ces for restrictors installation (5 screws).
Wall finish material
thickness (tile, etc.)
3/8” - 1-3/16”
(10-30 mm)
Fit screws
from inside
case
Support angles
Shield to rest
on 2 supports
Push shield
forward
Heat shield
(shown for top vent outlet)
Top & rear stand-off s
Installation
Remove rear support
QUALIFIED
INSTALLER
Summary of Contents for HORIZON 534JN