![Valor HORIZON 534JN Installation & Owner'S Manual Download Page 21](http://html1.mh-extra.com/html/valor/horizon-534jn/horizon-534jn_installation-and-owners-manual_3647126021.webp)
21
Mantel depth “A”
1”
(25 mm)
2”
(51 mm)
3”
(76 mm)
4”–5”
(102–127 mm)
6”
(152 mm)
7”
(178 mm)
8”–12” max.
(203–305 mm) max.
Mantel clearance “B”
7”
(178 mm)
8”
(203 mm)
9”
(229 mm)
10”
(254 mm)
11”
(279 mm)
12”
(305 mm)
14”
(356 mm)
Dimensions
Mantel
36”
(914 mm)
min.
See table
A
B
23-1/8”
(587 mm)
to
r
ear v
e
nt c
e
nt
er
33-1/2”
(850 mm)
14”
(355 mm)
Gas line
32-3/16” (817 mm)
29-3/16” (742 mm)
29-3/4”
(756 mm)
26-3/4”
(680 mm)
26-3/4”
(679 mm)
3” (75 mm) min.
To side wall from
inner frame
in front of
the appliance
X
Stand-offs
7” (180 mm)
From finished
wall front
to top vent
Stand-offs
4-1/2”
(114 mm)
1-1/2”
(38 mm)
16”
(406 mm)
7-7/8”
(199 mm)
Fronts and Trims
For fronts and trims dimensions, refer to instructions
provided with each kit.
Floor/Hearth
This appliance is approved for installation directly on
combustible material such as plywood and so on. Vinyl,
carpet, and soft fl ooring require sheet metal extending
the whole width and depth under the appliance.
This appliance does not require a hearth. Combustible
fl ooring may extend up to the front of the unit.
Combustible Materials Specifi cations
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that
can ignite and burn, whether fl ame proofed or not,
or plastered or unplastered shall be considered
combustible materials.
Non-Combustible Materials Specifi cations
Material which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or any combination
thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 °C shall be considered
non-combustible materials.
QUALIFIED
INSTALLER
Summary of Contents for HORIZON 534JN
Page 56: ......