INSTALLER’S GUIDE
Page 14
6 A P P L I A N C E I N S T A L L A T I O N
6.1
Installing To A Hearth
6.1.1
Place the fire centrally on the hearth making sure that the spigot lines up with the
spigot hole in the closure plate. Gently slide the appliance into place. The spigot must
enter the closure plate to a depth of at least 25mm.
6.1.2
Level the fire by loosening the lock nuts and turning the levelling screws in the feet
up or down as required while they bear on the hearth. When the fire is level and square
to the wall, retighten the lock nuts.
6.2
Wall Mounting
The fixing hole positions in relation to the
flue spigot opening are shown in figure 9.
Mark these positions on the wall. The
positions can alternatively be marked by
placing the fire in position and marking the
wall through the holes in the back panel.
Drill and plug the holes using no. 10 wall
plugs. Place the fire in position and secure
with four no. 10 x 2in. woodscrews.
6.3
Gas Supply Connection
8mm rigid tubing must be used to connect
the gas supply to the appliance. An olive
and nut are provided for connection to the
“T” connector on the appliance. The
connector can be rotated to allow connection
from either side or the rear. The connector
includes a valve for isolating the gas supply.
The closure plate has a cut-out for rear connection. Seal the gap between the cut-out and
the supply pipe.
Pressure check the installation pipework for gas soundness. In the United Kingdom check
in accordance with the current edition of BS6891. In the Republic of Ireland check in
accordance with the rules in force.
6.4
Radiants Installation
Important:
Fit the radiants ensuring that there rear face rests against the horizontal ribs
in the rear panel. There will be a small gap between their bottom front edge and the
retaining channel at the front of the radiant box.
Figure 9 Wall fixing holes