INSTALLER’S GUIDE
Page 12
Figure 6. Closure plate
Figure 5.
Pilot spark gap
knob to the spindle. Depress the knob and while keeping it
depressed, turn to the 1/IGN position. A spark should track
from the electrode pin to the thermocouple tip. If there is
no spark or incorrect tracking, check the spark gap between
the electrode wire and thermocouple tip. See figure 5.
If the spark gap is correct, check the ignition wiring.
5.3.9.
If the fire is fitted to a recessed fireplace, an
extension flue spigot up to a maximum total length of
125mm may be used. The extension must be a tight fit over
the flue spigot and be secured by two self tapping screws.
Note the minimum
clearance required as
shown in figure 2.
5.4
Fit The Closure Plate
See figure 6.
The closure plate has an
opening at the bottom for
a central gas feed pipe.
The gap between the pipe
and this opening should
be sealed with tape after
connection. If a central
feed pipe is not required
the opening should be
completely sealed with
tape.