INSTALLER’S GUIDE
Page 13
5.4.1
Hearth mounting
See figure 7.
The closure plate must be fitted and sealed to
the hearth and fireplace opening using a
suitable heat resistant material. If necessary
cut the closure plate but make sure that it
overlaps the fireplace opening sufficiently to
allow satisfactory sealing. Make sure that the
rectangular air relief opening is fully within
the fireplace opening.
5.4.2
Wall mounting
See figure 8.
The closure plate must be fitted and sealed to
the hearth and fireplace opening using a
suitable heat resistant material. If necessary
cut the closure plate but make sure that it
overlaps the fireplace opening sufficiently to
allow satisfactory sealing. Make sure that the
rectangular air relief opening is fully
within the fireplace opening.
The bottom of the appliance must be
at least 50mm above any carpet or
other floor covering. To achieve
this, the bottom of the flue spigot
opening must be at least 495mm
above the finished floor covering.
5.4.3
Check the flue pull with
closure plate fitted by applying a
lighted match or smoke match to the
flue spigot opening in the closure
plate and observe the smoke. If there
is a definite flow continue with the
installation. If not check the fitting
of the closure plate. The fireplace
flue pull check described in section
5.2 should have confirmed that the
fireplace itself is satisfactory.
Figure 8 Closure Plate for Wall Mounting
Figure 7 Closure Plate for Hearth
Mounting