Model
JN
JP
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
36,000
36,000
Input Minimum (Btu/h)
19,000
21,000
Manifold Pressure (in w.c.)
3.5”
10”
Minimum Supply Pressure
(in w.c.)
5”
11”
Maximum Supply Pressure
(in w.c.)
10”
14”
Main Burner Injector Marking
1000
50
Pilot Injector Marking
51
30
Min. Rate By-Pass Screw
220
160
Specifi cations
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/CSA
2.33-2014 American National Standard / CSA Standard
for
Vented Gas Fireplace Heaters
for use in Canada
and USA, and to CGA 2.17-91
High Altitude Standard in
Canada
. This appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15
Testing
method for measuring annual
fi
replace e
ffi
ciencies
.
The installation must conform to local codes or, in the
absence of local codes, with the
National Fuel Gas Code,
ANSI Z223.1/NFPA 54
or the
Natural Gas and Propane
Installation Code CAN/CGA-B149.1
. Only qualifi ed
licensed or trained personnel should install this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA
70
or the
Canadian Electrical Code, CSA C22.1
.
Ratings
*High Altitude Installations
I
nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 2200JN is used with natural gas.
Heater engine 2200JP is used with propane gas.
This appliance is designed and approved as a
supplemental heater and provides the potential
for most energy conservation when used while
attended. The use of an alternate primary heat
source is advisable.
The supply pressure
must be between the
limits shown in the
Ratings
section above.
The supply connection
is 1/2” NPT male and
located on the rear left side of the fi rebox. A shut-off
valve (supplied) is required on the supply line to isolate
the unit during service. See
Supply Gas Installation
section for details.
Conversion Kits
The 2200J LX2 is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kit for further information.
Electrical
The 2200J is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power to
operate the interior lighting, the optional 2200ULK
Underbed Lighting Kit or 1270RBK Remote Blower Kit.
LDK HeatShift Duct Kit
The 2200J must be installed with the LDK HeatShift
Duct Kit, a convection system that redistributes the
warm air fl ow away from the fi replace opening to a
more desirable location using natural convection,
without use of a fan.
The warm air fl ow may be relocated to a position higher
up the wall, out the sidewalls, or even to another room.
The result is much cooler wall temperatures above the
fi replace opening for locating televisions, artwork, etc.
Please note that the framing and mantel clearances
are aff ected by the installation of the LDK.
Refer
to the installation manual packed with the kit for more
information.
QUALIFIED
INSTALLER