43
Appliance rear view
Electrical
box cover
Gas
inlet
tube
RBWSK
wire
harness
inlet
RBWSK
power
connector
RBWSK
white connector
Installation
The fi replace’s upper decorative lighting is connected
to the v-module box located behind the appliance’s
front panel below the window. It is hidden under the
valve shield. The v-module is powered by a three-prong
plug plugged into a receptacle inside the appliance
case, at the rear, on the left-hand side.
1. At the back of the fi replace case, on the left-hand
side, remove the electrical box cover (4 screws).
2. Remove the knock-out covers according to the
number of electrical connections needed (1 for
incoming power, 1 for optional 2200ULK–Underbed
Lighting Kit’s dimmer switch).
3. Rough in the wiring harness for the
RBWSK—
Remote Battery & Wall Switch Kit
. Thread through
one of the holes to the left of the electrical panel
both the power connector and the white connector
end of the wire harness to reach the receiver at the
front of the appliance.
4.
If installing the optional 2200ULK—Underbed
Lighting Kit, do it now
so you can connect it to the
electrical wiring while the appliance is not in fi nal
position. Follow instructions provided with the ULK
kit for installation into the fi rebox.
5. Refi t the electrical box cover.
6. Remove the 4 screws retaining the appliance to its
pallet. Snap off the feet attached to the pallet and
discard or recycle.
7. With great care not to cut yourself on the sharp feet,
set the appliance
partially
into the framing keeping
in mind the need to access the rear of the appliance
to connect the electrical wires.