6. GAS SUPPLY CONNECTION
A nut and olive are provided for an 8mm pipe inlet connection to the ‘T’ connector at the
bottom front of the appliance. The ‘T’ connector can be rotated to allow a connection
from any direction. The ‘T’ connector includes a valve for isolating the gas supply and a
pressure test point.
The supply pipe must be
rigid material. Flexible
pipe must not be used.
This appliance is
designed for a concealed
supply pipe connection
routed through the
opening at the back of
the convection box.
Before the appliance is
fitted into the fireplace
it will be necessary to
extend the supply line
so that it will project
through the hole in the
back of the convection
box and run to the ‘T’ connector at the front. The pipe run from the supply line up to the
rear opening in the convection box must be kept away from the area which will be taken
by the convection box when it is installed (See figure 4).
Note that the centre of the appliance inlet ‘T’ connector is 20mm above the fireplace
floor.
The inlet ‘T’ connector should be fitted to the supply pipe at this stage. The access
opening at the rear of the convector box is sized to accept the “T” connector.
Figure 4 Fireplace convection box & debris catchment
area