OPERATING INSTRUCTIONS FOR CONTROL PANEL

Start button

Press the button to turn the ventilation unit on and off. 

When the indicator is lit, the unit is on.

Carbon dioxide adjustment

Press the button to turn carbon dioxide adjustment on and 

off. When the indicator is lit, the adjustment is on.

Humidity adjustment

Press the button to turn humidity adjustment on and off. 

When the indicator is lit, the adjustment is on.

Post-heating

Press the button to turn post-heating on and off. The 

summer function is on when the indicator is not lit.

Scrolling up

With this button you can scroll the displays upward.

Scrolling down

With this button you can scroll the displays downward.

Increase button

Use this button to increase values.

Decrease button

Use this button to decrease values.

3

4

1

5

6

7

8

1.1 Keyboard

2

Power failure

After a power failure, the unit starts at minimum fan speed. 

The adjustments and setpoints chosen will remain in the 

memory of the unit in spite of the power failure.

Main display

Fan speed can be changed in this display with the + 

and – buttons (see Section 1.1, fi gure items 7 and 8).

Fan speed (3).
Supply air temperature (21°C).
Time.
Filter guard alarm.

Maintenance reminder alarm.
Fireplace/booster switch on. The fi replace/booster switch is 

activated in this display by simultaneously pressing down the 

+ and – buttons for 2 seconds.
Week-clock control on.

3
21

10:20

Ventilation operating menus

Main display

2.1. Main display and change of fan speed

2.2 

Moving to the Settings menu

To settings menu
see manual

In order to move to the Settings menu, 

press the + and – buttons simultaneously. 

In the Settings menu you can change 

setpoints for the ventilation unit.

2.3 

Week-clock control

Week program
on

Week-clock control can be switched 

on with the + button and off with the – 

button. Week-clock control is on when 

the week-clock control symbol is in the 

main display. In week clock control, 

the base fan speed and supply air 

temperature of the unit are adjusted in 

accordance with the programme as 

described in Section 4.1.

2.4 

Content display

RH 35% 

RH2 

40%

CO2 

0821 PPM

The content display shows humidity 

and carbon dioxide content. The 

corresponding sensors are required 

(options).

2.5 

Temperature display

Out 20  

in 20

Sup. 20 

Exh. 20

The temperature display shows the 

temperatures of outdoor air, indoor air, 

supply air and exhaust air. The accuracy 

of the temperature sensors is ±2 °C.

2.6 

Setting supply air temperature

Temp. setting
20C

Supply air temperature is changed with 

the + and – buttons.

1. 

Control panel operation

2. Operating menu

3. 

Settings menu

You can move to the Settings menu from the Operating menu as described in Section 2.2
The displays of the Settings menu (Sections 3.1–3.29) can be scrolled with the scrolling buttons (see Section 1., 

items 5 and 6 in the fi gure).

3.1 

Resetting maintenance reminder

Mainten. reset 
Press + and –

The maintenance reminder is reset 

by pressing the + and – buttons 

simultaneously. This turns out the 

maintenance reminder symbol ( ) in the 

main display.

3.2 

Choosing maintenance reminder interval

Maintenance rem.
04

The interval for the maintenance 

reminder is selected with the + and 

– buttons. The maintenance reminder 

interval refers to months.

3.3  

Choosing language version

Kieli / Language
English

The desired language is chosen with the 

+ and – buttons.

3.4 

Adjusting time

Adjust time
Press + and -

You can adjust time by simultaneously 

pressing the + and – buttons. See 

separate instructions in 4.2.

1
21C

10:20

The displays of the Operating menu (Sections 2.1–2.6) can be scrolled with the scrolling buttons 

(see Section 1, fi gure items 5 and 6).

Summary of Contents for 096 SE L

Page 1: ...erating maintenance and technical instructions Electrical connection 230 V 50 Hz 5 1 A plug Degree of protection provided by enclosures IP 34 Fans Extract air 89 dm3 s 100 Pa direct current DC Supply...

Page 2: ...ring result 1 to 2 carbon dioxide sensors can be connected as options to the VALLOX 096 SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at the control panel Th...

Page 3: ...heating indicator light Maintenance reminder symbol Maintenance reminder The maintenance reminder switches on the maintenance reminder symbol on the main display of the control panel at defined interv...

Page 4: ...menu you can change setpoints for the ventilation unit 2 3 Week clock control Week program on Week clock control can be switched on with the button and off with the button Week clock control is on wh...

Page 5: ...water or electric radiator is selected with the and buttons depending on the type of post heating radiator the unit is equipped with Note Choosing the wrong type of post heating may cause a faulty pos...

Page 6: ...ttons The rotation speed of the extract air fan can be decreased by decreasing the percentage Move the cursor with the arrow keys and change values with the and buttons Note that to exit and save when...

Page 7: ...By using original Vallox filters you ensure good operation of the ventilation unit and the best filtering result The replacement interval of filters depends on dust content in ambient air It is recomm...

Page 8: ...you wish to detach the fan lift it upwards and crank the plastic lock to the right using for instance a chisel gure 6 The fan then falls down and can be pulled out of the unit Disconnect the quick co...

Page 9: ...t message is displayed and the unit operates at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type C...

Page 10: ...ing range E Extract air fan S Supply air fan Input power total W Air flow max dm3 s SFP SFP Specific Fan Power recommended value 2 5 kW m3 s At a lower total pressure SFP will be smaller at this speed...

Page 11: ...P W M 5 4 3 2 1 M 2x0 25 3x0 25 BN WT BN GN connection box on top of the unit 5 3 10 1 FAN CONTROL 0 10 V DC A B M S S 1 2 S S RH1 RH2 RS 485 BUS FAULT SIGNAL FIREPLACE SWITCH 12x0 25mm2 N GND L1 L 1...

Page 12: ...t state In this case remove one of the control panels and change the address of the other panel The above mentioned situation can arise in connection with the later installation of an additional contr...

Page 13: ...t protective enclosure the unit must be located in a place with no acoustic disturbance storerooms technical rooms etc Wall mounting VALLOX 096 SE is mounted on the wall with a mounting plate as shown...

Page 14: ...ting plate in place Then 4 332 544 600 600 push a rubber damper and washer to each thread bar all the way into the cup of the plate and turn the nut Shorten the lower ends of the thread bars so that t...

Page 15: ...l 3467200 10 Filter stand 3464500 No Part Code 11 G4 coarse filter 978045 extract air 12 Bypass duct assembly 3475100 indicate if right or left handed 13 Damper motor 930613 14 Extract air outlet 9850...

Page 16: ...1 09 602E 3 12 2013 PDF...

Reviews: