Vallox

096

SE

© VALLOX • We reserve the right to make changes without prior notice.

What the units include can vary depending on the sales area.

TECHNICAL DATA

600

Model R

Model L

121

143

143

121

Dimensions and duct outlets

Duct outlets, model R

Inner diameter of female outlet collar 

ø 125 mm
1. Supply air to dwelling 
2. Extract air from dwelling to unit
3. Exhaust air out
4. Outdoor air to unit 

Duct outlets, model L

Inner diameter of female outlet collar 

ø 125 mm
1. Exhaust air out
2. Outdoor air to unit 
3. Supply air to dwelling 
4. Extract air from dwelling to unit

Fan 

speeds

(V)

Extract air 

fl ow 

(l/s)

Combined input 

power of fans 

W

1

14

12

2

24

21

3

34

29

4

44

42

5

54

65

6

64

96

7

73

130

8

89

223

Supply/extract air volumes

Sound values 

25 

50 

75 

100 

125 

150 

175 

200 

225 

250 

275 

300 

325 

350 

375 

400 

425 

450 

475 

500 

10  15  20  25  30  35  40  45  50  55  60  65  70  75  80  85  90  95  100 

E1

SFP 1,5

SFP 2,0

SFP 1,0

S1

S2

E2 S3

E3

S4

S6

E6

S7

E7

S8

E8

S5

E5

E4

Pa 

93

102

298

363

600

141

459

407

430

600

545

55

3

1

4

2

Location of condensing water 

outlets, R and L models

Measuring points

Measuring points after the connection 

outlet. Fan curves indicate the total 

pressure available for duct losses.

Input powers of fans

Model R in 

the fi gure

Extract air

Supply air

Recommended 

operating range

E = Extract air fan

S = Supply air fan

Input power (total) (W)

Air fl ow (max.) (dm

3

/s)

SFP =

SFP (Specifi c Fan Power) recommended value <2.5 (kW m

3

/s)

At a lower total pressure, SFP will be smaller at this speed.

Volume fl ow rate

Pressure loss in ducts. T

otal pressure.

Sound power level in supply air duct

(one duct) by octave band L

W

, dB

Sound power level in extract air duct

(one duct) by octave band L

W

, dB

ADJUSTMENT POSITION/AIR FLOW dm

3

/s

ADJUSTMENT POSITION/AIR FLOW dm

3

/s

Adjustment position

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

Air fl ow dm

3

/s

10,6

25,2

38,1

46,6

53,8

65,6

72,9

76,0

12,0

27,6

36,7

44,2

50,5

61,0

70,4

76,4

Medium 

frequen-

cy of the 

octave 

band 

Hz

63

39

52

61

62

64

71

69

68

26

30

40

44

47

53

54

57

125

36

45

51

56

58

62

65

66

24

34

40

46

49

53

57

57

250

41

51

57

60

62

65

67

68

22

33

39

42

45

49

53

54

500

38

50

54

57

60

63

65

66

28

39

44

47

49

53

55

56

1000

34

48

54

57

59

62

64

65

23

36

42

45

48

51

54

55

2000

24

43

50

55

57

61

64

65

13

24

31

35

37

41

43

44

4000

16

32

42

47

49

54

56

58

16

17

21

24

26

30

33

33

8000

21

21

27

34

38

44

48

49

21

21

21

21

21

22

23

24

L

W

,dB 

L

WA

, dB(A)

45

57

64

66

69

73

74

74

33

43

49

52

55

59

62

63

39

52

58

61

64

67

69

70

28

39

45

48

51

54

57

57

Sound pressure level dB (A) coming from the unit through the envelope 

in the rooms where the unit has been installed

(10m

2

  sound absorption)

Vallox 096 SE 

ADJUSTMENT POSITION/AIR FLOW dm

3

/s

1

2

3

4

5

6

7

8

14/15 31/30 48/44 60/54 68/62 82/74

92/83

98/89

L

pA

, dB (A)

23

29

35

38

41

44

46

47

Summary of Contents for 096 SE L

Page 1: ...erating maintenance and technical instructions Electrical connection 230 V 50 Hz 5 1 A plug Degree of protection provided by enclosures IP 34 Fans Extract air 89 dm3 s 100 Pa direct current DC Supply...

Page 2: ...ring result 1 to 2 carbon dioxide sensors can be connected as options to the VALLOX 096 SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at the control panel Th...

Page 3: ...heating indicator light Maintenance reminder symbol Maintenance reminder The maintenance reminder switches on the maintenance reminder symbol on the main display of the control panel at defined interv...

Page 4: ...menu you can change setpoints for the ventilation unit 2 3 Week clock control Week program on Week clock control can be switched on with the button and off with the button Week clock control is on wh...

Page 5: ...water or electric radiator is selected with the and buttons depending on the type of post heating radiator the unit is equipped with Note Choosing the wrong type of post heating may cause a faulty pos...

Page 6: ...ttons The rotation speed of the extract air fan can be decreased by decreasing the percentage Move the cursor with the arrow keys and change values with the and buttons Note that to exit and save when...

Page 7: ...By using original Vallox filters you ensure good operation of the ventilation unit and the best filtering result The replacement interval of filters depends on dust content in ambient air It is recomm...

Page 8: ...you wish to detach the fan lift it upwards and crank the plastic lock to the right using for instance a chisel gure 6 The fan then falls down and can be pulled out of the unit Disconnect the quick co...

Page 9: ...t message is displayed and the unit operates at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type C...

Page 10: ...ing range E Extract air fan S Supply air fan Input power total W Air flow max dm3 s SFP SFP Specific Fan Power recommended value 2 5 kW m3 s At a lower total pressure SFP will be smaller at this speed...

Page 11: ...P W M 5 4 3 2 1 M 2x0 25 3x0 25 BN WT BN GN connection box on top of the unit 5 3 10 1 FAN CONTROL 0 10 V DC A B M S S 1 2 S S RH1 RH2 RS 485 BUS FAULT SIGNAL FIREPLACE SWITCH 12x0 25mm2 N GND L1 L 1...

Page 12: ...t state In this case remove one of the control panels and change the address of the other panel The above mentioned situation can arise in connection with the later installation of an additional contr...

Page 13: ...t protective enclosure the unit must be located in a place with no acoustic disturbance storerooms technical rooms etc Wall mounting VALLOX 096 SE is mounted on the wall with a mounting plate as shown...

Page 14: ...ting plate in place Then 4 332 544 600 600 push a rubber damper and washer to each thread bar all the way into the cup of the plate and turn the nut Shorten the lower ends of the thread bars so that t...

Page 15: ...l 3467200 10 Filter stand 3464500 No Part Code 11 G4 coarse filter 978045 extract air 12 Bypass duct assembly 3475100 indicate if right or left handed 13 Damper motor 930613 14 Extract air outlet 9850...

Page 16: ...1 09 602E 3 12 2013 PDF...

Reviews: