Vallox

096

SE

© VALLOX • We reserve the right to make changes without prior notice.
What the units include can vary depending on the sales area.

OPERATING INSTRUCTIONS

Adjustment of supply air temperature 

and summer/winter function

The temperature of air coming to the dwelling can be adjusted between 

circa +10 °C and +30 °C. When there is a light on the post-heating 

indicator, post-heating is activated and the unit heats air as needed. 

The need for heating depends on the setpoint of supply air temperature. 
When there is no light on the post-heating indicator, post-heating is off. 

This means that the summer function is activated for the ventilation unit. 

The unit has a motorised summer/winter function. When the summer 

function is on, the heat recovery cell is bypassed as soon as outdoor 

air temperature has risen above the setpoint. See the setpoint for cell 

bypass, factory s12 ºC. When outdoor air temperature goes 

below the setpoint (factory s12 °C), the unit starts to recover 

heat.
Two  different  kinds  of  supply  air  temperature  adjustment  can  be 

chosen at the unit: constant temperature control or cascade control. 

In constant temperature control, the unit controls the temperature of 

supply air directly in accordance with the measurement information 

on the temperature of supply air blown to the ventilation area. In 

cascade control, the unit controls supply air temperature according 

to the temperature of air extracted from the ventilation area. The unit 

calculates the difference between the air extracted and the setpoint for 

supply air and uses this difference to control the need for post-heating.

Winter function of ventilation unit

A  set  of  parameters  has  been  set  at  the  factory  for  the  freezing  of 

the heat recovery cell (3.21 and 3.22).When these parameters are 

undercut, the ventilation unit melts the heat recovery cell utilising the 

heat of extract air. 
Melting is done by stopping the supply air fan (3.20. Choosing melting 

mode) or by bypassing the heat recovery cell on the supply air side 

(factory setting).
If the bypassing the heat recovery cell is chosen as the melting mode, 

the relationship between the supply and extract air fl ows does not 

change. This prevents the formation of a vacuum inside, which may be 

harmful in some cases. In this case the electric resistor heats the cold 

air coming from outside during the melting period to the temperature 

desired (2.6. Setting supply air temperature). If the temperature desired 

is high compared to outdoor air temperature, the unit decreases the 

supply and extract air fl ows in order to attain the desired supply air 

Remember!

Switch post-heating off when it starts to get too warm 

in the dwelling because of warm weathers.

Switch post-heating on again when it gets cooler in 

autumn.

Post-heating indicator light

Maintenance reminder 

symbol

Maintenance reminder

•   The maintenance reminder switches on the maintenance 

reminder symbol ( ) on the main display of the control panel 

at defi ned intervals, the factory setting being 4 months.

•   The maintenance reminder symbol is acknowledged at 

the main display of the control panel. (See the operating 

instructions for control panel, Section 3.1.)

•   The interval can be set between 1 and 15 months at the 

control panel.

Fireplace switch function/booster

Fireplace switch function

(See the operating instructions for control panel, Section 3.12.)
•   The fi replace switch stops the extract air fan for 15 minutes and 

produces overpressure in the ventilation zone. This makes it easier 

to light a fi replace.

 

The function is started on the main display of the control panel by 

simultaneously pressing and holding down the + and – buttons for 

2 seconds.

•   The function can also be started at a separate auto-reset push-

button switch, wired from the connection box of the unit for 

example to a wall in the fi replace room. Upon each pressing, 

the stopping function continues for 15 minutes (the switch is not 

included in the delivery).

•   During the function, the fi replace/booster switch symbol ( ) is 

visible on the main display of the control panel.

NOTE! The starting of the extract air fan may weaken 

draught in the fi replace! In winter, this situation may 

disturb the winter function of the unit. The situation will 

normalise in a while, after the fi replace function stops.

Booster switch function

(See the operating instructions for control panel, Section 3.12.)
•   The booster switch function raises fan speed to the set maximum 

fan speed for 45 minutes.

 

The function is started on the main display of the control panel by 

simultaneously pressing and holding down the + and – buttons for 

2 seconds.

•   The function can also be started at a separate auto-reset push-

button switch, wired from the connection box of the unit to for 

instance a wall in a classroom. Upon each pressing, the boosting 

function continues for 45 minutes.

•   During the function, the fi replace/booster switch symbol ( ) is 

visible in the main display of the control panel.

•   The function is chosen at the control panel.

Fireplace/booster switch symbol

Fault signal relay (remote monitoring)

•   The fault signal relay has potential-free contacts 

(24 VDC, 1 A).

•   The contacts provide information on various failure modes of 

the unit.

•   Alarm of high carbon dioxide content switches the relay at 

1-second intervals.

•   In other fault situations, the contacts are closed.

temperature.
A normal melting period varies from 15 to 45 minutes depending on 

the amount of ice and the volume of the extract air fl ow.
The unit operates optimally on the factory settings in normal operation 

in dwellings and detached houses. The parameters only need to be 

touched in extreme problem situations. Examples of such situations are 

high humidity loads such as a swimming pool or if there is a detrimental 

amount of ice in the exhaust air duct.

Summary of Contents for 096 SE L

Page 1: ...erating maintenance and technical instructions Electrical connection 230 V 50 Hz 5 1 A plug Degree of protection provided by enclosures IP 34 Fans Extract air 89 dm3 s 100 Pa direct current DC Supply...

Page 2: ...ring result 1 to 2 carbon dioxide sensors can be connected as options to the VALLOX 096 SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at the control panel Th...

Page 3: ...heating indicator light Maintenance reminder symbol Maintenance reminder The maintenance reminder switches on the maintenance reminder symbol on the main display of the control panel at defined interv...

Page 4: ...menu you can change setpoints for the ventilation unit 2 3 Week clock control Week program on Week clock control can be switched on with the button and off with the button Week clock control is on wh...

Page 5: ...water or electric radiator is selected with the and buttons depending on the type of post heating radiator the unit is equipped with Note Choosing the wrong type of post heating may cause a faulty pos...

Page 6: ...ttons The rotation speed of the extract air fan can be decreased by decreasing the percentage Move the cursor with the arrow keys and change values with the and buttons Note that to exit and save when...

Page 7: ...By using original Vallox filters you ensure good operation of the ventilation unit and the best filtering result The replacement interval of filters depends on dust content in ambient air It is recomm...

Page 8: ...you wish to detach the fan lift it upwards and crank the plastic lock to the right using for instance a chisel gure 6 The fan then falls down and can be pulled out of the unit Disconnect the quick co...

Page 9: ...t message is displayed and the unit operates at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type C...

Page 10: ...ing range E Extract air fan S Supply air fan Input power total W Air flow max dm3 s SFP SFP Specific Fan Power recommended value 2 5 kW m3 s At a lower total pressure SFP will be smaller at this speed...

Page 11: ...P W M 5 4 3 2 1 M 2x0 25 3x0 25 BN WT BN GN connection box on top of the unit 5 3 10 1 FAN CONTROL 0 10 V DC A B M S S 1 2 S S RH1 RH2 RS 485 BUS FAULT SIGNAL FIREPLACE SWITCH 12x0 25mm2 N GND L1 L 1...

Page 12: ...t state In this case remove one of the control panels and change the address of the other panel The above mentioned situation can arise in connection with the later installation of an additional contr...

Page 13: ...t protective enclosure the unit must be located in a place with no acoustic disturbance storerooms technical rooms etc Wall mounting VALLOX 096 SE is mounted on the wall with a mounting plate as shown...

Page 14: ...ting plate in place Then 4 332 544 600 600 push a rubber damper and washer to each thread bar all the way into the cup of the plate and turn the nut Shorten the lower ends of the thread bars so that t...

Page 15: ...l 3467200 10 Filter stand 3464500 No Part Code 11 G4 coarse filter 978045 extract air 12 Bypass duct assembly 3475100 indicate if right or left handed 13 Damper motor 930613 14 Extract air outlet 9850...

Page 16: ...1 09 602E 3 12 2013 PDF...

Reviews: