ELECTRICAL SAFETY STATEMENT
Installation Of The Valley Electric Irrigation Machine - European Union Only
Valmont Industries Inc. does not install a differential (ground fault) circuit breaker in the control panel of the
Valley electric irrigation machine because the standards of protection vary according to country of destination.
The distributor must provide and install a differential (ground fault) circuit breaker that meets the standards of
the country where the Valley irrigation machine is installed.
In the European Union, differential circuit breaker protection is fixed at a maximum of 24 volts.
Good grounding of the Valley irrigation machine is required.
• If resistance to ground is lower than 80 ohms, a differential (ground fault) circuit breaker of 300 mA will meet
requirements.
• If resistance to ground is between 80 and 800 ohms, a differential (ground fault) circuit breaker of 30 mA will
meet requirements.
The power supply installation and inspection of equipment protection components or systems are the respon-
sibility of the installer. Valmont Industries, Inc. is not responsible for the failure of equipment protection compo-
nents or systems not of their manufacture.
Valley pivot irrigation machines receiving power from a generator must have a cable connected from the irriga-
tion machine structure to a ground rod and another cable from the irrigation machine structure to the ground
terminal on generator in order for the differential (ground fault) circuit breaker to work.
The linear irrigation machines equipped with a generator are not equipped with a ground rod but must have a
cable connected from the linear irrigation machine structure to the ground terminal of the generator in order for
the differential (ground fault) circuit breaker to work.
• The resistance between the irrigation machine and the generator must be substantially below 80 ohms.
About This Manual
Information contained in this manual applies to Valley Center Pivot and its use with the 7000, 8000 and 8120
Series of spans.
For proper operation of the Center Pivot machine, the Control Panel Owner’s Manual and Center Pivot Owner’s
Manual must be used together.
The Control Panel Owner’s Manual includes safety guidelines and explains the basic operation of the control
panel itself, including how to start/stop the machine, change running direction and change water application
amounts.
All Owner’s, operators and maintenance personnel MUST read and understand the Control Panel Owner’s
Manual and the Center Pivot Owner’s Manual.
All information in this manual is based on information available at the time of printing. Valmont Industries Inc.
reserves the right to make changes at any time without notice and without incurring any obligation. Specifica-
tions are applicable to equipment sold within the United States and may vary outside of the United States.
Ancillary Equipment Warranty
The owner is responsible for warranty registration of all ancillary equipment such as but not limited to engines,
pumps and generators with its respective manufacturer.
Summary of Contents for Center Pivot 7000 Series
Page 2: ...2 Center Pivot 7000 8000 8120 Series ...
Page 18: ...18 Center Pivot 7000 8000 8120 Series SAFETY Safety Decals WARNING WARNING WARNING WARNING ...
Page 30: ...30 Center Pivot 7000 8000 8120 Series OVERVIEW ...
Page 36: ...36 Center Pivot 7000 8000 8120 Series OPERATION Towing Option ...
Page 40: ...40 Center Pivot 7000 8000 8120 Series OPERATION Towing Option ...
Page 46: ...46 Center Pivot 7000 8000 8120 Series OPERATION Towing Option ...
Page 62: ...62 Center Pivot 7000 8000 8120 Series OPERATION Towing Option ...
Page 102: ...102 Center Pivot 7000 8000 8120 Series MAINTENANCE ...