Center Pivot 7000, 8000, 8120 Series 105
TROUBLESHOOTING
Tower Ahead Shut Down
In a tower ahead shut down, the tower which is out of line and the farthest ahead fails to shut off and breaks
the safety circuit.
!
WARNING
• TO REDUCE THE POSSIBILITY OF STRUCTURAL DAMAGE, NEVER REVERSE THE DIRECTION OF
TRAVEL AFTER A TOWER AHEAD SHUT DOWN. AFTER MACHINE IS REPAIRED, ALWAYS OPER-
ATE IN THE SAME DIRECTION OF TRAVEL AS BEFORE THE SHUT DOWN. WHEN THE MACHINE
COMES BACK INTO ALIGNMENT THE DIRECTION CAN BE CHANGED.
Tower ahead shut downs typically occur because of a component failure in the tower box. Some causes of
tower ahead shut downs are; contactor failure, suppressor failure, run microswitch failure and binding of the
switch pivot arm. Call your Valley Dealer to diagnose and repair a tower ahead shut down. Refer to the control
panel Owners Manual for other TROUBLESHOOTING information.
DIRECTION
OF TRAVEL
TOWER AHEAD SHUT DOWN
CALL VALLEY DEALER