- 7 -
1- Product description -
Performance
Valeo
TM55 & TM65
conversion factors
The performance data below were measured under the following conditions:
• Compressor speed: 1450 rpm
• Suction gas temperature: 20°C
Conditions
Cooling Capacity Q and Power Consumption P
Cond.
temp (oC )
Pd
(MPaG)
Evap temp
(oC )
-10
-5
0
5
10
12.5
Ps (MPaG)
0.10
0.15
0.19
0.24
0.32
0.35
40
0.91
Q (kW)
17.29
22.96
28.21
33.92
42.18
45.71
P (kW)
6.30
7.02
7.53
8.10
8.68
8.90
50
1.21
Q (kW)
15.16
20.21
24.24
29.31
37.58
40.37
P (kW)
6.83
7.76
8.39
9.06
9.90
10.11
60
1.58
Q (kW)
12.66
17.30
20.80
25.28
32.10
34.56
P (kW)
7.35
8.43
9.17
9.95
11.02
11.35
Valeo
TM-65
performance data (R134a)
Conditions
Cooling Capacity Q and Power Consumption P
Cond.
temp (oC )
Pd
(MPaG)
Evap temp
(oC )
-10
-5
0
5
10
12.5
Ps (MPaG)
0.10
0.15
0.19
0.24
0.32
0.35
40
0.91
Q (kW)
14.73
19.68
23.88
29.30
37.23
40.31
P (kW)
5.31
5.96
6.39
6.77
7.21
7.36
50
1.21
Q (kW)
12.75
17.52
21.06
25.58
32.97
35.54
P (kW)
5.80
6.59
7.09
7.63
8.32
8.48
60
1.58
Q (kW)
10.53
14.42
17.60
21.39
28.16
30.65
P (kW)
6.28
7.21
7.84
8.52
9.38
9.63
Valeo
TM-55
performance data (R134a)
The performance data at different rotation speed can be approximated with the conversion factors
below.
1000
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0
2000
3000
4000
P
Q
Compressor speed (rpm)
Con
version f
act
ors
1450