Perform an opening in the exterior wall according to the size of the wall termination. From
outside, place the outside air inlet cap in the hole (open side down) and fasten the register to
the wall, with screws as shown (
Figure 21
). Place the insulated pipe over the register tube and
over the fireplace outside air connector (see
Figure 21
). At each end, carefully pull back the
insulation and plastic cover, exposing the flexible pipe. Attach the flexible pipe using
clamping rings. For a better seal, you may also use aluminum tape. Wrap the tape around the
joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic
cover back over the pipe. Secure the plastic in place using aluminum tape.