MC122 - MCP-4J Control Unit
Section 7 - Specifications
91
Section 7 - Specifications
Item
MCP-4J Unit, Horizontal
074xx087
074xx088
074xx089
074xx090
MCP-4J Unit, Vertical
074xx084
074xx085
074xx086
Control dimensions:
Height:
5.86" (x mm)
Depth:
10.11" (x mm)
Width:
9.95" (x mm)
Approximate weight:
12.5 lbs. (x)
Height:
12.5" (x mm)
Depth:
5.83” (x mm)
Width:
9.95" (x mm)
Approximate weight:
12.5 lbs. (2.49 kg)
Input voltage:
90-130, 200-240 VAC,
50-60 Hz (auto-selected)
90-130, 200-240 VAC,
50-60 Hz (auto-selected)
IP Rating
IP40
Number of channels:
4-channel operation with up to 10 programmable patterns per
channel
Glue pattern resolution:
0.01 in. or 1 mm
Minimum Glue Pattern Length
0” (0mm)
Maximum Glue Pattern Length
258.01” (6554mm)
Number of scanner inputs:
Up to 4 with scanner lockout
Glue pattern tolerance:
Less than 1 mm (0.4 inches) at 610 m/min (2000 ft/min)
Job storage memory:
100 jobs
Max Operating Ambient Temperature
60
o
C or 140
o
F
Miscellaneous:
Encoder-based or timer mode
Multi-valve, complex glue pattern capabilities
“Continuous” and “Stitch” pattern gluing
Adjustable minimum speed
Inch or metric calibration
CE compliant
Password protection for key system parameters
Integral fluid-flow control option (EPC)
Web break detection option
Batch count/production count
Programmable valve output voltages depending upon base
unit
Jam Detection (not on
horizontal units: 074xx087,
074xx088, 074xx089 or 074xx090
)
USB software update
USB and Micro-SD backup and restore
Max Valve Chart
Valve Type
300E
400E/EC
524E
540E
900E
9020
MX
MAC12
MAC24
Max Per Valve Channel
2 2 1
1
1
1
1
2 2
Max Per Unit
6 6 4
4
4
4
4
6 6
Summary of Contents for MCP-4J
Page 4: ......
Page 10: ...Table of Contents MC122 MCP 4J Control Unit 6 ...
Page 12: ...Section 1 Introduction MC122 MCP 4J Control Unit 2 ...
Page 20: ...Section 2 Safety and Use MC122 MCP 4J Control Unit 10 ...
Page 38: ...Section 3 Basic features MC122 MCP 4J Control Unit 28 Wiring the Scanner Cable Continued ...
Page 59: ...MC122 MCP 4J Control Unit Section 4 Programming 49 Protected Level Mode Continued ...
Page 100: ...Section 6 Maintenance MC122 MCP 4J Control Unit 90 ...
Page 102: ...Section 7 Specifications MC122 MCP 4J Control Unit 92 ...
Page 130: ...Section 8 Part Number List MC122 MCP 4J Control Unit 120 ...
Page 132: ...Section 9 Warranty MC122 MCP 4J Control Unit 122 ...
Page 134: ...Section 10 Service MC122 MCP 4J Control Unit 124 ...
Page 136: ...Appendix A Job Charts MC122 MCP 4J Control Unit 126 Job Number Job Name Description ...
Page 146: ...Appendix C Instruction Sheets for the MCP 4J MC122 MCP 4J Control Unit 136 ...
Page 156: ...MCP 4J Quick Start Guide IS0368 Valco Melton 10 Operator Panel ...