Configure the Valve/Channel Settings
The settings are preprogrammed for the specific application selected. It is best not to change any setting unless you
are a trained technician and/or have assistance from a member of the Valco Technical Assistance Team.
CAUTION!
Changing settings may bring unwanted consequences in the performance of your system.
Valco Cincinnati, Inc. recommends having a qualified technician setup your system
parameters. Otherwise, loss of production time may result from improper settings.
All screens for configuring the valves/channels are available
in all applications.
Compensation Time
On Compensation Time (Ton)
- This is the amount of time (in milliseconds) from when the valve is activated to when
the glue is applied. Increasing the "ON" Compensation Time will move the start of the pattern forward.
Off Compensation Time (Toff)
- This is the amount of time (in milliseconds) from when the valve is turned off to
when the adhesive application is stopped. Increasing the Off compensation time will make the glue line shorter.
Minimum Compensation Time (Tmin)
- This is the time the valve will be open, no matter what the pattern length, the
machine speed, and the "OFF" Compensation Times are set at.
Summary of Contents for MCP-4J
Page 4: ......
Page 10: ...Table of Contents MC122 MCP 4J Control Unit 6 ...
Page 12: ...Section 1 Introduction MC122 MCP 4J Control Unit 2 ...
Page 20: ...Section 2 Safety and Use MC122 MCP 4J Control Unit 10 ...
Page 38: ...Section 3 Basic features MC122 MCP 4J Control Unit 28 Wiring the Scanner Cable Continued ...
Page 59: ...MC122 MCP 4J Control Unit Section 4 Programming 49 Protected Level Mode Continued ...
Page 100: ...Section 6 Maintenance MC122 MCP 4J Control Unit 90 ...
Page 102: ...Section 7 Specifications MC122 MCP 4J Control Unit 92 ...
Page 130: ...Section 8 Part Number List MC122 MCP 4J Control Unit 120 ...
Page 132: ...Section 9 Warranty MC122 MCP 4J Control Unit 122 ...
Page 134: ...Section 10 Service MC122 MCP 4J Control Unit 124 ...
Page 136: ...Appendix A Job Charts MC122 MCP 4J Control Unit 126 Job Number Job Name Description ...
Page 146: ...Appendix C Instruction Sheets for the MCP 4J MC122 MCP 4J Control Unit 136 ...
Page 156: ...MCP 4J Quick Start Guide IS0368 Valco Melton 10 Operator Panel ...