MUS033202
18/10/2010
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
48
6.2. MAINTENANCE RECOMMENDATIONS:
The following table shows the frequency with which maintenance
operations should be performed
:
Frequency
Maintenance
Clean the outer surface of the equipment. Use a liquid
cleaner following the instructions of the adhesive that is
going to be use.
Inspect all the electric, pneumatic and hydraulic
connections. Replace or repair when necessary
Weekly
(40 hours)
Bleed the drain valve.
Change the air regulator filter.
6 Months
(2000 hours)
Clean tank grille.
Anyway, the frequency of this operation depends on the type of
adhesive used and the environmental conditions where the equipment
is placed.
6.3. MAINTENANCE PROCESSES:
6.3.1. Cleaning the equipment
Vacuum the dust or glue remains or remove with a soft cloth,
especially from the distributor and bleed valves.
Clean the control panel periodically with a soft cloth. Do not use
solvents, which could rust the controls.
Use a soft cloth to remove dust and glue remains from the cylinder,
valve and exchange.
If you use a cleaning agent, make sure that it is compatible with the
adhesive being employed.
When in doubt, contact the adhesive manufacturer.
6.3.2. Bleeding the air filter of the pressure regulator:
The air regulation unit is bled by tightening the lower button on the
filter.
The regulator filter will be changed when necessary depending on the
dirt that accumulates in the pneumatic network.