MUS033202
18/10/2010
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
42
Note:
Never operate the applicator if the tank is empty. If the quantity
of hot – melt material is very small the tank may overheat, leading to
the carbonisation of the HOT-MELT material and the formation of
deports inside the unit. This may lead to unnecessary downtimes later
on
.
Emptying the Tank:
Before emptying the tank, put on a face shield, gloves and long-sleeve
shirt to prevent possible burns caused by hot adhesive splashing.
1º Warm the equipment to the working temperature.
2º Reduce the air pressure to zero.
3º Eliminate system pressure by releasing the manual guns or
opening the bleed valve.
4º Place an appropriate container under the distributor to
collect the adhesive.
5º Unscrew the purging valve with a screw driver.
6º Increase the pressure a little until adhesive flows through
the purging valve and the distributor and tank empty.
7º Changing the filter and joints on the dismantled parts is
recommended once the tank is empty.
Filling tank