M007502200
12/07/2007
MELTON, S.L. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail:[email protected] http://www.melton.es
12
Press
to validate the changes. The display will then show:
* format data *
minimum press. Xx %
Where XX is the minimum pressure in % of the line pressure.
The control will maintain the minimum pressure until the calculation of
pressure is over that value.
Bead programming:
Following, the display shows the application parameters that can be set
between 0 and 5000.
When working in timer mode the display will show parameters T1 to T8.
Data Format xx
Channel x T1:xxxx ms
When working in encoder mode the display will show parameters L1 to
L8.
Data Format xx
Channel x L1:xxxx MM
Odd parameters are the spaces between the input signal and the start of
each of the 4 lines. Pair parameters represent the length of the line.
4.3.3 Test Valve menu:
This menu is used for the manual testing of the good operation of the
values mounted on each channel.
On/Off must be Off.
The display will show
Test Valve
Valve x
Where X is the channel to be tested. Modify this channel with the arrows
and press
to fire that values connected to that channel. This menu is
only available hen the control is enabled to work.
4.3.4 Reset Counter menu:
When entered, the display shows:
Reset Counter
Press ENTER 2 sec
Value 1 selects programming with rising edge and falling edge of
the start sensor (photocell).