146
PR-23 instruction manual
10.1.1 Transmitter program versions
The DTR program version can be updated over the Ethernet connection (see Chap-
ter 12). Contact your nearest representative for more information on how to update
your DTR program version.
Program version 4.07:
The DTR program version 4.07 is compatible with any DTR and any PR-23 sensor
with program version 1.00 or higher. This DTR program version contains following
new features:
–
DD-23 Divert Control Unit:
protocol versions 2 and 3.
–
Network booting for sensors:
Network booting of sensors from DTR files.
–
mA output:
Support for negative span for mA output.
–
Temperature bias:
Parameter for temperature bias.
–
Temperature hold:
An ability to hold temperature when concentration is held for
wash or external hold.
–
Slew rate limit filter:
New output filter method to limit the maximum change
from a measurement to the next.
–
Support for advanced http interface
–
Instrument tags:
An option to add instrument tags (max. 16 characters) to trans-
mitter and sensor information.
–
Wash fail status handling:
Wash recovery handling changed so that a wash fail-
ure status is not cleared if wash check was not passed. The error status will be
cleared when the wash check is passed.
Program version 3.0:
The DTR program version 3.0 is compatible with any DTR and any PR-23 sensor with
program version 1.00 or higher. This DTR program version contains following new
features:
–
Single sensor mode
for the intrinsically safe PR-23-...-IA refractometer system
(see Section 9.11). This mode combined with a special single connection H1 inter-
face card PR-10705 creates an Indicating transmitter STR.
–
Divert functionality
enables the DTR to function as a part of a Divert Control Sys-
tem used to control black liquor concentration in paper and pulp applications. Di-
vert mode only allows for one sensor per transmitter, but a standard DTR is used.
Program version 2.0:
The DTR program version 2.0 is compatible with any DTR and any PR-23 sensor with
program version 1.00 or higher. This DTR program version contains following new
features:
–
Instrument homepage and printable verification certificate
–
Multi-lingual user interface
–
Linear damping
–
Field sample soft key
Summary of Contents for K-PATENTS PR-23 AX Series
Page 1: ...IM EN PR23 v 2 00 Instruction Manual Vaisala K PATENTS Process Refractometer PR 23...
Page 2: ......
Page 4: ......
Page 17: ...2 Inline refractometer sensor 7 2 2 2 PR 23 mounting guide...
Page 26: ...16 PR 23 instruction manual...
Page 29: ...4 Prism wash systems 19 Figure 4 1 A prism wash system for steam non sanitary...
Page 30: ...20 PR 23 instruction manual Figure 4 2 A sanitary prism wash system for steam...
Page 32: ...22 PR 23 instruction manual Figure 4 5 Wiring for a prism wash system for steam...
Page 33: ...4 Prism wash systems 23 Figure 4 6 A prism wash system for high pressure water non sanitary...
Page 34: ...24 PR 23 instruction manual Figure 4 7 A sanitary prism wash system for high pressure water...
Page 35: ...4 Prism wash systems 25 Figure 4 8 Wiring for a prism wash system for high pressure water...
Page 40: ...30 PR 23 instruction manual...
Page 50: ...40 PR 23 instruction manual...
Page 72: ...62 PR 23 instruction manual...
Page 174: ...164 PR 23 instruction manual...
Page 179: ...11 Safe Drive 169 11 3 3 Safe Drive steam wash system parts...
Page 186: ...176 PR 23 instruction manual 11 4 2 Wiring Figure 11 9 PR 23 SD system wiring...
Page 204: ...194 PR 23 instruction manual Figure 11 19 Markings on the retractor handle...
Page 206: ...196 PR 23 instruction manual...
Page 218: ...208 PR 23 instruction manual...
Page 226: ...216 PR 23 instruction manual...
Page 230: ...220 PR 23 instruction manual...
Page 232: ...222...
Page 238: ...228...
Page 240: ...230...
Page 242: ...232...
Page 244: ...234...
Page 246: ...www vaisala com...