Hydraulics installation 5
0020291544_01 Hydraulic Station Installation and maintenance instructions
27
▶
For heating installations with solenoid valves or thermo-
statically controlled valves, install a bypass with bypass
valve in order to guarantee a volume flow of at least 40%.
5.2
Connecting the heat pump to the indoor unit
1
2
1
G 1 1/4" connection,
heating return to the
heat pump
2
G 1 1/4" connection,
heating flow from the
heat pump
1.
Blow or flush the supply pipes thoroughly prior to install-
ation.
2.
Connect the heat pump to the hydraulic station.
3.
Check whether the connections are leak-tight.
(
→
Page 36)
5.3
Connecting the domestic hot water
cylinder's heating flow and heating return
1
2
▶
Connect the domestic hot water cylinder's heating return
(1)
and heating flow
(2)
in accordance with the relevant
standards.
5.4
Connecting the building circuit
2
1
1.
Connect the filling device with the enclosed seal to the
product's heating return.
1
2
2.
Connect the building circuit's return
(1)
and flow
(2)
in
accordance with the relevant standards.
5.5
Installing the drain hose on the expansion
relief valve
1
1.
Install a drain hose
(1)
on the expansion relief valve.
2.
Install the expansion relief valve hose in a frost-free
environment and ensure that its routing ends in an open
drain where it is then visible.
3.
Terminate the drain hose in such a way that escaping
water or steam cannot cause injury to persons or dam-
age to electrical components.
4.
Open the expansion relief valve regularly in order to
remove scale deposition, and ensure that the device is
not blocked.