Appendix
0020291544_01 Hydraulic Station Installation and maintenance instructions
47
Setting level
Values
Unit
Increment, select, ex-
planation
Factory setting
Setting
Min.
Max.
T.0.42 Building circuit: Pressure
0
3
bar
0.1
T.0.43 Building circuit: Flow rate
0
4000
l/h
1
T.0.48 Air inlet temperature
-40
90
℃
0.1
T.0.55 Compressor outlet tem-
perature
-40
135
℃
0.1
T.0.56 Compressor inlet temper-
ature
-40
135
℃
0.1
T.0.57 EEV outlet temperature
-40
90
℃
T.0.59 Capacitor outlet temperat-
ure
-40
90
℃
0.1
T.0.63 High pressure
0
31.9
bar (abs)
0.1
T.0.64 Low pressure
0
8
bar (abs)
0.1
T.0.67 High-pressure switch
Closed
Open
Closed, Open
T.0.85 Evaporation temperature
-40
90
℃
0.1
T.0.86 Condensation temperature
-40
70
℃
0.1
T.0.87 Overheating target value
-40
90
K
0.1
T.0.88 Overheating actual value
-40
90
K
0.1
to 20 K are normal op-
erating parameters
T.0.89 Subcooling target value
-40
90
K
0.1
T.0.90 Subcooling actual value
-40
90
K
0.1
T.0.93 Compressor speed
0
120
Rotation/s
1
T.0.123 Temperature switch:
Compressor outlet
Open
Closed
Open, closed
T.1.02 DHW prioritising diverter
valve
Heating
Domestic
hot water
Heating, domestic hot
water
Heating
T.1.44 Cylinder temperature
-40
90
℃
0.1
T.1.46 Lockout contact S20
Closed
Open
Closed, Open
Closed
T.1.69 Outdoor temperature
-40
90
℃
0.1
T.1.70 System temperature
-40
90
℃
0.1
T.1.71 DCF status
Current value
No DCF signal
Validate DCF signal
Valid DCF signal
T.1.72 Lockout contact S21
Closed
Open
Closed, Open
Open
T.1.119 MO1 output
Off
On
Off, On
Off
T.1.124 Safety cut-out immersion
heater
Closed
Open
Closed, Open
Closed
T.1.125 MPI input
Current value
T.1.126 MO2 output
Off
On
Off, On
Off
T.1.127 MO3 output
Off
On
Off, On
Off
Installer level
→
Configuration
→
Language
Current language
Languages available for
selection
02 English
Contact details
→
Telephone
number
Phone number
0
–
9
Heat curve
2)
0.4
4.0
0.1
Summer sw.-off temp.
2)
10
90
℃
1
Heating biv. point
2)
-30
+20
℃
1
1)
See the overview of fault codes: Fault lists are only available, and can only be deleted, if faults have occurred.
2)
This parameter does not appear if a system control is connected.
3)
This parameter is only available in the products for Spain