Appendix
58
Installation and maintenance instructions Hydraulic Station 0020291544_01
L
Inspection and maintenance work
#
Maintenance work
Interval
1
Checking the pre-charge pressure of the expansion vessel
Annually
39
2
Check that the prioritising diverter valve can move easily (visually/audibly)
Annually
3
Checking the electronics boxes, removing dust from the ventilation slits
Annually
M
Characteristic values for the internal temperature sensors, hydraulic circuit
Sensors: TT620 TT650
Temperature (°C)
Resistance (ohms)
0
33400
5
25902
10
20247
15
15950
20
12657
25
10115
30
8138
35
6589
40
5367
45
4398
50
3624
55
3002
60
2500
65
2092
70
1759
75
1486
80
1260
85
1074
90
918
95
788
100
680
105
588
110
510
N
Characteristic values for the VR10 internal temperature sensors, cylinder temper-
ature
Temperature (°C)
Resistance (ohms)
-40
88130
-35
64710
-30
47770
-25
35440
-20
26460
-15
19900
-10
15090
-5
11520
0
8870
5
6890
10
5390
15
4240