Hydraulic installation
24
Installation and maintenance instructions ecoTEC plus 0020134833_01
6
6.2
Connecting the hot and cold water
1
2
3
4
5
7
6
6.1 Fitting the hot and cold water connection
>
Make the domestic hot and cold water connections as
shown.
>
Ensure correct water pressure and flow requirements
and that any expansion can be accommodated with the
cold supply pipe work (
¬ section 2.5.7
).
6.3
Connecting pipe connections between the
layered storage tank and the boiler
2
4
1
3
6.2
Fitting the pipe connections between the layered storage
tank and the boiler
>
Fit the supplied pipe elbows and straight pipelines in the
specified sequence.
i
The pipe elbows (
1
) and (
2
) must be fitted first.
6.4
Connecting the heating flow and heating
return
1
2
3
4
5
11
12
10
13
9
8
7
6
6.3
Fitting the heating flow and heating return
>
Connect the water as shown.
6.5
Low loss header
A low loss header disconnects the boiler from the heating
system. The system is no longer dependent on the remain-
ing feed head of the boiler. In conjunction with the boiler
circulation pump, the low loss header ensures that a suffi-
ciently high minimum quantity of water is always circulating
through the boiler. No electrical accessories are required in
order to use a low loss header.