Instructions for Use, Installation and Servicing ecoMAX pro
16
7 Flue
1)
In addition, the terminal should not be nearer
than 150mm to an opening in the building fabric
formed for the purpose of accommodating a built-in
element such as a window.
2)
Dimension B,C and D; These clearances may
be reduced to 25 mm without affecting the
performance of the boiler. In order to ensure that
the condensate plume does not affect adjacent
surfaces the terminal should be extended as shown
in Fig 7.4.
3)
Dimension F; This clearance may be reduced
to 25 mm without affecting the performance of
the boiler. However, in order to ensure that the
condensate plume does not affect adjacent surfaces
a clearance of 300 mm is preferred.
4)
BS 5440-1 It is recommended that a fanned flue
terminal should be positioned as follows:
a) at least 2m from an opening in a building directly
opposite, and
b) so that the products of combustion are not
directly directed to discharge across a boundary.
For IE, recommendations are given in the current
edition of IS 813.
Fig 7.2
12677
A
BCD
A
G
H,
I
F J
B F M
L
L
K
K
G
G
F F
E
A
A
Fig 7.1
12676
TERMINAL POSITION
mm
A1) Directly below an opening, above an opening
or horizontal to an opening i.e. air brick,
opening window or other, etc
300
B Below gutters, soil pipes or drain pipes
752)
C Below eaves
2002)
D Below balconies
2002)
E From vertical drain pipes and soil pipes
25
F From internal or external corners
3003)
G Above ground, roof or balcony
300
H From a surface facing a terminal
6004)
I
From a terminal facing a terminal
1200
K Vertically from a terminal on the same wall
1500
L Horizontally from a terminal on the same wall 300
M Distance from adjacent wall for vertical Flue 500
Summary of Contents for ecoMAX pro 18E
Page 37: ...Instructions for Use Installation and Servicing ecoMAX pro 37 Declaration of Conformity 17...
Page 38: ...Instructions for Use Installation and Servicing ecoMAX pro 38...
Page 39: ...Instructions for Use Installation and Servicing ecoMAX pro 39...
Page 40: ...0020005557_04 GB 08 2006 Subject to alteration...