34
8 Troubleshooting
Instructions for installation and servicing ecoMAX
34
Key to Fault codes
Code
Meaning
Cause
F.0
Flow–NTC:
– NTC broken
– NTC cable broken
Flow–NTC cable defective/broken NTC faulty
– Defective connection at NTC
– Defective connection at electronics
F.1
Return–NTC:
– NTC broken
– NTC cable broken
Return–NTC cable defective/broken NTC faulty
– Defective connection at NTC
– Defective connection at electronics
F.10
Short circuit – flow–NTC (< 130 °C)
NTC– plug shorted to casing, NTC defective
F.11
Short circuit – return–NTC (< 130 °C)
NTC– plug shorted to casing
NTC defective
F.13
Short circuit in tank sensor
NTC defective, earth leak/short circuit in cable loom,
damp plug connection
F.20
Over heat cut off activated
Maximum temperature exceeded
No water in system
F.22
Low water or no water in appliance
Pump defective
Pump lead defective
F.23
Water level low
Pump obstructed, pump running at lower capacity,
Temperature range too wide
Air in appliance, system pressure too low,
flow and backflow NTC reversed
F.24
Water level low
Pump obstructed, pump running at lower capacity,
Temperature rises too fast
ir in appliance, system pressure too low,
flow and backflow NTC reversed
F.25
Water Switch
Water Switch - plug disconnected
System pressure too low
Waterswitch activated
F.27
No demand to gas valve
Electronic board defective
Gas valve defective
No gas
Insufficient gas
Incorrect gas valve adjustment
F.28
Boiler goes to lock out
Electrode defective
Ignition lead defect
Electronic igniter defective
Check air inlet duct
F.29
Flame extinguished re–ignition unsuccessful
Gas supply absent or insufficient
Check flue duct
F.32
Fan turning–speed malfunction
Fan unit obstructed, plug–in fan connector not
(too fast at start–up)
correctly inserted, Hall sensor defective, fault in cable
loom, defective electronic control system
F.60
Gas–valve c defective
Short circuit/earth (ground) leak in cable loom to gas
valves, gas valve assembly defective (earth/ground
leak from coils), electronic control system defective
Short circuit/earth (ground) leak in cable loom to gas
F.61
Gas–valve control – defective
valves, gas valve assembly defective (earth/ground
leak from coils), electronic control system defective
F.62
Defective gas–valve closure mechanism
Leak in gas valve assembly, electronic fault
F.63
EEPROM error
Electronic fault
F.64
Electronic system/sensor fault
Short circuit in flow or backflow NTC,
electronic fault
F.65
Electronic system temperature too high
Electronic system affected by external heat source,
electronic fault
F.67
Electronic fault in flame system
Electronic fault
(non–plausible flame signal)
Table 8.3